TRACKING FILTER AND UV LAMP SERVICE TIME 

Under normal conditions, the Filter should be changed out every 180 days. Under normal conditions, 

the UV Lamp should be changed out every 365 days. Contact your local Field Service Contractor or 
Distributor for replacement parts. Replacement part numbers are provided in parts list section of this 
manual.

There are several ways to track the remaining useful life of media Filter and UV Lamp:

1. 

Use Field Controls Healthy Home iAQ APP on a smart device

2. 

Use Field Controls Healthy Home System Control Plus (HHSC+) device

3. 

Use Field Controls Manual Tracking Filter/Lamp Sticker

Healthy Home iAQ APP  

Healthy Home iAQ APP           on a smart device will automatically alert the homeowner when either 
the fi lter or UV lamp should be replaced.  This app can be confi gured to notify the homeowner by 
email or by visual notifi cation thru the smart device. An optional feature of this APP can be confi g-
ured to notify your HVAC contractor.  Refer to Field Controls Healthy Home iAQ APP – Filter and UV 
Lamp Tracking instruction sheet (doc: 78010001000). This document is available on the Field Con-
trols Web Site (www.FieldControls.com). The Healthy Home iAQ APP is a free down load from Apple 
Store or Google play for your mobile device. Search Healthy Home iAQ.

Healthy Home System Control Plus (HHSC+)

Healthy Home System Control Plus (HHSC+) will automatically alert the homeowner via HHSC+ status 
LED will turn red and display on the screen to replace the HVAC fi lter and/or UV Lamp.  The Filter 
and UV Lamp replacement period is adjustable on HHSC+ device. Refer to Field Controls Healthy 
Home System Control Plus instruction sheet (doc: 46633800) for additional information.  This docu-
ment is available on the Field Controls Web Site (www.FieldControls.com). The HHSC+ can be 
purchased separately. Contact your local contractor. 

Manual Tracking Filter/Lamp Sticker 

Manual Tracking Filter/Lamp Sticker (p/n: 75000002000) can be manually installed on the door of 
the Trio1200/2000 unit by the homeowner or contractor.  The sticker is designed to handle two Filter 
replacements to every one UV Lamp replacement.  The replacement dates must be manual written on 
the sticker by the homeowner or HVAC contractor. The fi lter/lamp replacement sticker can be pur-
chased from Field Controls as a separate item.

Summary of Contents for Healthy Home System

Page 1: ...HEALTHY HOME AIR PURIFICATION SYSTEM MODELS TRIO 1200 TRIO 2000 INSTALLATION AND OPERATION Field Controls 2630 Airport Road Kinston NC 28504 252 522 3031 www fieldcontrols com ...

Page 2: ...ave ultraviolet light during period of non air flow and is self cleaning If there is build up blocking the catalytic cells sit the unit on end on a flat surface with electrical enclosure facing up Use low pressure compressed air to blow the surface of the catalytic cells free of blockage Do not install insulation within 76MM or 3 inches of Luminaries Access for service is required when mounting abov...

Page 3: ...ctivating itself during periods of non use or no airflow The cost of operation is less than 07 cents per day See operating cost section The Trio 1200 2000 air purification system combines three unique technologies to protect people against indoor air pollutants Photo catalytic technology PCO combined with high efficiency electro statically super charged MERV13 particulate filter and UVC germicidal lig...

Page 4: ... COST OF CONTINUOUS 24 HR PER DAY OPERATION PER MONTH Electricity cost per kilowatt hour 06 kw hr 08 kw hr 10 kw hr TRIO 32 25 kw hours cost per month 1 93 2 58 3 22 During periods where the fan unit is being operated for the sole purpose of air purification usually during the spring and fall season when there is no requirement for heating or cooling the cost of running a 1 2 horsepower fan unit wi...

Page 5: ...Fig 4 3 Unplug UVC germicidal lamps loosen retaining knobs and remove UVC germicidal lamps Fig 5 6 4 Replace UVC germicidal lamps re tension retaining knobs and replace plug ins 5 Replace Photocatalytic module and filter secure door and re insert power cord check view ports to ensure lamp illumination NOTE NOTE Ensure filter and photocatalytic module are installed in proper air flow sequence FIG 3 FI...

Page 6: ...n sheet doc 78010001000 This document is available on the Field Con trols Web Site www FieldControls com The Healthy Home iAQ APP is a free down load from Apple Store or Google play for your mobile device Search Healthy Home iAQ Healthy Home System Control Plus HHSC Healthy Home System Control Plus HHSC will automatically alert the homeowner via HHSC status LED will turn red and display on the scr...

Page 7: ...nobs and remove the inside module from the outer case 2 Take care not to bend or distort the outer metal enclosure 3 Mount the outer case to the support plenum NOTE NOTE Do not use a screw length that will extend into or penetrate the inside module containing the TiO2 catalyst or filter cartridge 4 In some cases the foot print of the air handler may be larger or smaller than the outer enclosure of ...

Page 8: ... the inner module into the outer encasement and tighten locking knobs finger tight Make sure the inner module will freely slide in and out of the outside enclosure 8 Plug in the power cord to any 120vac outlet and check both sight ports to make sure both lamps are illuminated Ultraviolet lamps must remain on at all times regardless of thermostat or HHSC Control settings 9 Set the thermostat or the ...

Page 9: ...page 9 Designed in accordance with UL 1598 and CAN CSA C22 2 ...

Page 10: ...page 10 FIG 10 Electrical Diagram WIRING DIAGRAM PRODUCT LABEL PLACEMENT Label is shipped in bagged parts seperately and should be placed on unit as noted below ...

Page 11: ...page 11 Denotes transformer installed on product shipped prior to 2016 ...

Page 12: ...hone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC P N 46638700 Rev K 09 18 WARRANTY For warranty information about this or any Field Controls product visit www fieldcontrols com ...

Reviews: