Field Controls CK-91FV Quick Start Manual Download Page 1

www.fi eldcontrols.com

Please retain these instructions after installation.

This device 

MUST

 be installed by a qualifi ed agency in accordance with the manufacturer's installation instructions. The defi nition of 

a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged 
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 
precautions required, and has complied with all the requirements of the authority having jurisdiction.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

24 VAC SYSTEM CONTROL KIT

Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced 
appliances with a 24 VAC Gas Valve and a 30-millivolt controlled Natural or L.P. Gas Water Heater.

 

ITEMS INCLUDED IN KIT:

 

1- Junction box with mounted pressure switch and post purge timer

 

1- Fan control gas pressure switch with built in post purge option

 

1- 2 ft. length of 

1

4

" aluminum tubing

 

1- 

1

8

" NPT x 3" pipe nipple

 

1- 

1

8

" NPT x 

1

4

" OD tubing elbow

 

1- 

1

8

" NPT pipe tee

 

1- TCA-1 Thermocouple Adaptor

 

1- 6 ft. length of 12-2 wire

 

1- 8" jumper wire

 

2- Flexible conduit connector

 

2- GSK-3 Spillage Switch

 

1- 4" MG1 Barometric Draft Control

 

1- 

1

4

" tubing connector

Model: CK-91FV

P/N 46285300 Rev F 01/18

Summary of Contents for CK-91FV

Page 1: ...D COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION Installation Date Installed By Phone 24 VAC SYSTEM CONTROL KIT Designed for use with the SWG Series Power Venter for controlling Natural Gas or L P...

Page 2: ...asten the flexible conduit from the SWG Venter into the conduit connector Mount the CK 91FV junction box or installer supplied junction box onto the wall or floor joist without straining the flexible...

Page 3: ...TION DO NOT use the supplied collar when mounting draft control to Type B Vent Pipe Install by using a Type B Vent Pipe Tee 1 Install a vent pipe reducer or increaser into the inner pipe and fasten us...

Page 4: ...properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch which will result in a hazardous condition and bodily harm THERMOSTAT HEAT ANTICIPATOR A...

Page 5: ...ignition module or gas valve if standing pilot which would normally be 24 volts hot on a call for heat With spark ignition systems this terminal could be TH W 24 V THS or T1 depending on the spark ig...

Page 6: ...Install the GSK spill switches per instruction and connect to the red wire and the thermal door switch per diagram Wire the venter motor and controls in accordance with the National Electrical Code ma...

Page 7: ...couple circuit halting the gas flow to the pilot and burner 3 Wait 2 to 3 minutes Reset the spillage switches and light the pilot then perform a second safety spillage test Steps 1 and 2 CAUTION If fo...

Page 8: ...Pressure Switch 46284200 GSK 3 Spillage Switch 46086400 Post Purge Timer 46282800 Pressure Switch 46083000 TCA 1 Thermocouple Adaptor 46082700 REPAIR AND REPLACEMENT PARTS TROUBLE SHOOTING HINTS 1 Ven...

Reviews: