10.  Slide the filter drawer out of the base.  Remove one the four filters from its plastic bag 

and place it in the drawer with arrow/carbon side up. (See Figure 6) 

11.  Slide the filter drawer with filter back into the base unit. Press firmly until drawer 

catches. 

NOTE:

 The positive catch eliminates vibration and ensures proper function of the filter.

 

12.  Unwind the power cord from underneath the unit and insert plug into any standard 120-

volt outlet. 

13.  Turn the speed control knob clockwise to turn the unit on.  After the fan has started, the LED lights will show a 

continuous “GREEN” color and the LCD will indicate 365 days left for the lamp and 90 days for the filter. See  
Figure 7) 

NOTE:

  

If the LCD display reads differently use the point of a pen or paper clip to press the “reset” button beside 

the LED for either the lamp or the filter to reset the days as shown above.

 

IV. OPERATION 

1.  Place the UV-500C in the desired area; plug the power cord into a standard 120-volt wall receptacle. 

2.  Turn the speed control knob clockwise to turn on the unit and to adjust the motor/fan speed to the desired airflow. 

(Refer to Figure 7) 

3.  After the fan has started, the LED light for the lamp and filter will show a continuous “GREEN” color indicating 

proper unit operation. 

IV. MAINTENANCE 

1.  Replace 10”x 10” intake filter every 90 days.  The LED beside the filter indicator will turn 

“RED” and the display will say “FILTER:  CHANGE” when it is time to replace the filter. 

2.  Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps 

maximum output intensity. The lamp should operate continuously for maximum lamp life 
and light effectiveness.  The LED beside the lamp indicator will turn “RED” and the 
display will say “LAMP:  CHANGE” when it is time to replace the filter. 

VI. REPLACEMENT PROCEDURES 

R

EPLACING THE 

UV 

LAMP

 

VERY IMPORTANT:

 

Turn the speed control switch on unit to ‘OFF’ position and unplug 

unit from outlet or turn off power to the unit before replacing the UV lamp.

 

1.  Loosen the screw on the lamp access door on the back of the UV-500C.  (See Figure 8) 

2.  Open the door to expose the lamp connection.  (See Figure 9) 

WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or

blindness. 

Never operate the UV-Aire™ Air Purifying System with the UV lamp access door open

. Avoid touching the glass portion of the

lamp with your hands. 

Figure 6 

Figure 9

 

 

Figure 7 

Motor Fan 
Speed Control 
Knob 

Lamp LED

Filter LED

Figure 8 

Summary of Contents for 46476300

Page 1: ...V Aire Air Purifying System with the UV lamp access door open WARNING DO NOT mount this unit outdoors This product is designed for indoor installation only WARNING To avoid electrical shock hazard do not operate in wet environment ITEMS INCLUDED IN SYSTEM 1 UV Aire UV 500C unit 1 Ultra Violet Lamp Individually Boxed 1 Instruction Sheet 4 10 x 10 x 1 Filters 1 Bagged Parts containing lamp connector...

Page 2: ...ve the lamp connector from the bagged parts provided 3 Remove the UV 500C from its protective plastic bag WARNING DO NOT PLUG INTO WALL OUTLET 4 Connect the UV lamp to the lamp connector knob See Figure 1 5 Clean the lamp with the alcohol swab provided See Figure 2 NOTE Dirt and fingerprints will reduce lamp output and effectiveness 6 Open the lamp access door on the back of the unit 7 Insert the ...

Page 3: ...has started the LED light for the lamp and filter will show a continuous GREEN color indicating proper unit operation IV MAINTENANCE 1 Replace 10 x 10 intake filter every 90 days The LED beside the filter indicator will turn RED and the display will say FILTER CHANGE when it is time to replace the filter 2 Replace your UV Aire Air Purifying System lamp once a year to maintain the lamps maximum out...

Page 4: ...listed below At the time of request for warranty service the purchaser must present proof of purchase documentation which includes the date of purchase for example a receipt or sales slip If the malfunction or failure is a result of defects covered by this warranty Field will at its option repair the product or replace it and return it to the purchaser This warranty is limited to the original reta...

Reviews: