The multiplicative coefficient A1 is set to 0.001 because the measuring channel
K1 records the value of the instantaneous flow in litres and the sum channel K6
is set according to the specification in m3.
For example, set the SMS alert parameters as shown below:
Warning SMS No.5 will be sent immediately (
Delay=0
) after the sum on channel
K6 exceeds the value of 20 m3. The same SMS will be sent again after the value
on channel K6 drops below 5 m3 (
Hysteresis
parameter = 15, i.e. 20-15=5 m3)
and the sum value on channel K6 increases back to 20 m3.