DRAIN ADAPTERS
Please install the darin adapters beneath the heater prior to installation.. You can add 5/8 hose to
the adapters to direct the condensation water.
PLUMBING
·
A typical installation on a pool with a small pump, such as ½, ¾ hp pump with 1 1/2” pvc or
flexible pipes, just requires pipes to go in from the bottom and exit thru top.
·
For stronger systems, with 1.0 Hp and larger pumps, and 2 inch plumbing systems, a bypass
system should be installed.
·
If The heat pump is connected to a filtration circuit with a by-pass valve; The bypass valve
should be partially opened (throttled), while all the other valves should be completely
opened. We suggest to open bypass 50% then adjust until the lowest volume of water going
through the heater, but no error messages ( EE-3, PL, EE1) are present. This will give
enough water to the heater, and not restrict your flow.
·
The old system BYPASS path usually consists of 3 valves. The New FIBROPOOL BY PASS
VALVE is just 1 valve. That makes it possible to adjust water flow which passes through heat
pump .