![Fibocom LC116-LA Hardware Manual Download Page 40](http://html1.mh-extra.com/html/fibocom/lc116-la/lc116-la_hardware-manual_2286852040.webp)
4 Circuit Design
Copyright © Fibocom Wireless Inc.
38
4.2.3
Power-off
The module supports the following three power-off modes.
Table 38. Power-off mode
Power-off Mode
Power-off Method
Applicable Scenario
Low-voltage
power-off
When VBAT voltage is too low or
power-down occurs, the module
will be powered off.
The module does not log out
from a base station.
Hardware
Pull down PWRKEY pin for 3s to 8s. Hardware normal power-off
AT Power-off
AT+PWROFF
Software power-off
When the module is working properly, do not cut off the power supply of
the module immediately to avoid damaging the internal Flash. It is
strongly recommended to power off the module by the PWRKEY pin or the
module by PWRKEY or AT command before cutting AT command before
cutting off the power supply.
When using the AT command to power off the module, ensure that the
PWRKEY pin is always at the high level after the power-off command is
executed. Otherwise, the module will automatically power on again.