The WPC-04R consists of the following parts: 

 

Item No. 

Qty. 

Component part No. 

Description 

1 1 42-15032-00 

Timer 

41-15004-08 

8 Position Terminal Block 

12 

10-15089-01 

M3 Screw, 4MM Length 

10-15089-07 

M3 Screw, 14MM Length 

5 1 37-15000-00 

Relay 

6 1 02-15287-00 

Base 

Plate 

02-15286-00 

Timer and Switch Plate 

8 1 02-15285-00 

Relay 

Cover 

38-15012-00 

3 Position Rocker Switch 

10 

A10670 

Screw, 8-32 x .25” 

11 4 14-15032-00 

PCB 

Standoff 

12 1 94-15108-01 

PCB 

13 1 04-15045-00 

Enclosure 

14 1 94-15092-00 

WPC 

Repeater 

Accessory Items:

 

FP 1/2 

Temperature Freeze Device 

WE-65 

65 ft Repeater Cord Extension Kit 

DL-HUB 

Direct Light Hub Connection Kit 

 

10 

13 

14 

12 

11 

Summary of Contents for WPC-04R

Page 1: ...to UL STD 508 Certified to CSA STD C22 2 No 14 Installation Instructions Read these instructions in their entirety before performing any installation work Rated for use on 110 120VAC 60Hz and 220 240...

Page 2: ...Length 5 1 37 15000 00 Relay 6 1 02 15287 00 Base Plate 7 1 02 15286 00 Timer and Switch Plate 8 1 02 15285 00 Relay Cover 9 1 38 15012 00 3 Position Rocker Switch 10 3 A10670 Screw 8 32 x 25 11 4 14...

Page 3: ...or installation instructions Light circuit is rated for 8Amp 120VAC Max Basic safety precautions should be observed when operating the WPC 04R product and other associated equipment 1 A qualified elec...

Page 4: ...common to the Timeclocks T C NEUTRAL In 20 Amp circuit breaker in the main breaker panel and connect the HOT wires from the WPC 04R in l es of in on to inal stall a inimum GFCI GROUND NEUTRAL 120V LIN...

Page 5: ...oduct to the C 1 switch pull wires from the product WPC 04R through conduits connected to the bottom of the WPC 04R As illustrated connect the light that will be operated by the Rocker Switch to the L...

Page 6: ...ONNECTING A 240VAC PUMP Connect the 240VAC pump to the relay as illustrated Connect the Line Power to a 240VAC Circuit Breaker on the breaker panel Circuit Breaker should be rated to correspond to Hor...

Page 7: ...into groove between the Dome and Base approximately where the locking dimples are located Pry the Dome out of on of the locking dimples Then carefully insert the small flathead screwdriver into the g...

Page 8: ...ch terminal To turn OFF the device manually flip the Rocker Switch to the MIDDLE or OFF position NOTE In the OFF position the wireless remote operation will be bypassed To re enable the wireless remot...

Page 9: ...OTE Each tab represents 15 minutes of operation and tabs set inwards towards the center is for OFF operations and ON when the tabs are set outwards as illustrated In the example below the Pump will be...

Page 10: ...http www fiberstars com For Freeze Protect Switch For Freeze Protect Switch 79 15103 00 REV B Page 10 of 11...

Page 11: ...http www fiberstars com 79 15103 00 REV B Page 11 of 11...

Reviews: