Protection class
IEC 60529 IP44
Enviromental conditions
Usage -40....+60oC (dry or moist conditions)
Storage -40....+60oC (dry conditions)
Enclosure material & size
Stainless steel and aluminium, 180 x 40mm
Weight approx. 230g ( no probes )
Batteries
3pcs. 1.5V IEC LR03 (AAA)
Sound indicator
Internal speaker
LED indicators
Green LED,12 red LED’s
for power and signal
strength indication
Technical Specification
Fiberpowertech Plutovej 7 8722 Hedensted Denmark phone: +45 75 89 22 99 mail: [email protected] www.fiberpowertech.dk
Compact Receiver - sondes overview - additional setup
6,4 mm
4,6 mm
7,5 mm
9,0mm
18,0mm
Diameter
84 mm
94 mm
114 mm
138mm
85 mm
Length
2,3 m
9 h
M5F
8mm
2,3 m
9 h
M3,5F
6mm
5,1 m
6 h
M5/6F
9-12mm
5,7 m
10 h
M5/6F
14-20mm
10,0m
20 h
M5/6/10/12F/M
21-42mm
Free air range
Operating time 20
o
C
Threads
* Recommended air pressure for straight duct calibration - < 5 bar - use sonde catcher for impact absorption
Straight duct
calibration ID*
1
2
3
4
5
DANGER!! When using duct sondes always mount sonde catcher including sponge on the ducts end.
Microduct sondes are
small transmitter sondes
intended for calibrating
and locating fiber optic
microducts and their
blockages.