background image

 

 

 

Other

 

Considerations

 

FiberPlex

 

Auxiliary

 

Control

 

(FAC)

 

Interface

 

On

 

the

 

rear

 

of

 

the

 

unit,

 

near

 

the

 

opticalCON

 

DUO

 

connector,

 

are

 

two

 

RJ

11

 

jacks,

 

one

 

marked

 

“In”

 

and

 

the

 

other,

 

“Thru.”

 

These

 

support

 

a

 

proprietary,

 

115.2

 

kBaud

 

RS

422

 

serial

 

protocol

 

that

 

enables

 

a

 

controlling

 

device

 

to

 

poll

 

the

 

status

 

of

 

connected

 

devices.

 

Up

 

to

 

255

 

units

 

can

 

be

 

daisy

chained

 

on

 

one

 

link,

 

with

 

the

 

“In”

 

as

 

the

 

upstream

 

link

 

(eventually

 

leading

 

to

 

the

 

controller)

 

and

 

the

 

“Thru”

 

as

 

the

 

downstream

 

link.

 

 

Figure

 

8

 

FAC

 

Control

 

on

 

the

 

rear

 

of

 

the

 

WDM16

 

 

The

 

pinouts

 

of

 

the

 

connectors

 

are

 

as

 

follows:

 

Connector

 

Pin

 

Function

 

1

 

Rx

 

+

 

(to

 

the

 

WDM)

 

2

 

RX

 

 

(to

 

the

 

WDM)

 

3

 

TX

 

 

(from

 

the

 

WDM)

 

4

 

TX+

 

(from

 

the

 

WDM)

 

A

 

standard

 

crossover

 

RJ11

 

cable

 

can

 

be

 

used

 

to

 

daisychain

 

units

 

together.

 

For

 

the

 

WDM,

 

the

 

following

 

information

 

can

 

be

 

accessed:

 

 

Temperature

 

of

 

the

 

logic

 

board

 

and

 

power

 

supplies

 

 

Channel

 

status

 

(SFP

 

inserted,

 

signal

 

present,

 

transmit

 

good)

 

 

Identification

 

of

 

SFP

 

models

 

and

 

manufacturer

 

 

Status

 

of

 

cooling

 

fans,

 

including

 

level

 

and

 

operational

 

status

 

 

Power

 

supply

 

Voltages,

 

temperatures

 

and

 

switching

 

frequency

 

An

 

example

 

application

 

available

 

from

 

FiberPlex

 

appears

 

as

 

follows:

 

 

Contact

 

FiberPlex

 

for

 

more

 

information

 

as

 

to

 

availability

 

of

 

this

 

and

 

other

 

applications.

 

 

Summary of Contents for WDM16

Page 1: ...USER MANUAL Active Wave Division Multiplexer WDM16 WDM8A WDM8B...

Page 2: ......

Page 3: ...us the apparatus has been exposed to rain or moisture does not operate normally or has been dropped The apparatus shall not be exposed to dripping or splashing No objects filled with liquids such as v...

Page 4: ...I equipment must be earthed separately Grounding the unit is one of the measures for protection against electrical shock hazard dangerous body currents Hazardous voltage may not only be caused by defe...

Page 5: ...sal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer...

Page 6: ...Active Wave Division Multiplexer Combines 16 or 8 optical channels into a single fiber pair Each channel independently supports data rates from 155 MB up to 3 GB SMPTE compatible internal fiber optics...

Page 7: ...the number of Active Wave Division channels and the associated internal wavelengths that are supported The chassis dimensions and power supplies remain identical The WDM16 supports all of the 16 stand...

Page 8: ...if there is mechanical damage or if the unit fails to operate notify FiberPlex and make the shipping materials available for the carrier s inspection Chassis Mounting Mount the chassis using fastener...

Page 9: ...ystem is functioning normally PS1 Shows status indication of the power supply in PS Slot 1 top slot Color indications can be interpreted using the following table LED State Condition Off No power supp...

Page 10: ...INF 8074i more information later in this manual They are fixed bi directional ports and cannot support dual TX or dual RX SFPs Any standard MSA complaint SFP can be used in these slots including but n...

Page 11: ...Power Supply Module AC Inlet Power is provided through a Neutrik powerCON TRUE1 connector Connect to 100 240 VAC power source using the supplied AC power cord Fuse Compartment Contains the fuse for th...

Page 12: ...lete redundancy The second supply can be inserted at any time in the unused power supply slot Insert the supply first then apply external AC power The PSMAC and the WDM16 8 support hot swapping of the...

Page 13: ...REMOVE CAP REPLACE FUSE SCREWDRIVER SLOT Figure 6 Replacing the Fuse in the PSMAC...

Page 14: ...e SFP Module has a Bail Clasp close the Bail Clasp before inserting the SFP Module 4 With the gold finger connector on the bottom and the label on the top line up the SFP Module with the empty cage an...

Page 15: ...Tab Pull the tab gently in a straight outward motion until it disengages from the port Make sure the tab is not twisted when pulling as it may become disconnected from the SFP Module Slide Tab With y...

Page 16: ...nnecting the cable requires grasping the cable connector with your full hand and pulling back the release ring with your thumb and fore finger while pulling the connector straight out See Neutrik docu...

Page 17: ...the WDM16 The pinouts of the connectors are as follows Connector Pin Function 1 Rx to the WDM 2 RX to the WDM 3 TX from the WDM 4 TX from the WDM A standard crossover RJ11 cable can be used to daisych...

Page 18: ...gical conditions allowing the longer sequences of ones or zeros to pass without error The Fiberplex Technologies WDM16 and WDM8 Active Coarse Wave Division Multiplexer has Video Enhanced optics pre in...

Page 19: ......

Page 20: ...WDM16 Specifications 19 00 482 6 3 00 76 2 3 47 88 1 18 33 465 5 25 6 4 17 25 438 2 13 12 333 2 13 62 346 0 Figure 10 WDM16 8 Overall Dimensions...

Page 21: ...ax Data Rate MB 155 3000 Recommended Jitter psec 40 Operating Voltage VDC 3 3 Maximum Current mA 350 Internal CDWM Optical Interfaces Min Typ Max Aggregate Optical Launch Level dB 1 0 1 Aggregate Rece...

Page 22: ...n 286 mm 2 625 in 67 mm 1 25 in 32 mm 1 1 lb 0 5 kg SPECIFICATIONS AC POWER SUPPLY Min Typ Max Power Supply Input Voltage VAC 100 110 240 Input Frequency Hz 40 400 Power Factor 92 Output 1Voltage VDC...

Page 23: ......

Page 24: ...WDMUM 1401 18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100...

Reviews: