Power

 

Requirements

 

and

 

Mounting

 

Flexible

 

mounting

 

allows

 

the

 

TIS

8632

 

to

 

be

 

rack

 

shelf

 

mounted

 

or

 

used

 

in

 

a

 

standalone

 

configuration.

 

Up

 

to

 

3

 

TIS

8632

 

units

 

can

 

be

 

mounted

 

on

 

a

 

TDR

01

 

shelf

 

and

 

powered

 

by

 

a

 

single,

 

integral

 

cable.

 

Alternately,

 

the

 

TIS

8632

 

can

 

be

 

used

 

in

 

a

 

standalone

 

application

 

when

 

paired

 

with

 

the

 

included

 

DC

 

wall

 

adaptor.

 

Standalone

 

For

 

standalone

 

applications,

 

the

 

TIS

8632

 

comes

 

with

 

(4)

 

peel

 

and

 

stick

 

rubber

 

feet.

 

Simply

 

peel

 

the

 

paper

 

backing

 

from

 

the

 

rubber

 

foot

 

and

 

affix

 

to

 

four

 

corners

 

of

 

the

 

TIS

8632.

 

Surface

 

Mount

 

Surface

 

mounting

 

on

 

a

 

wall,

 

desk,

 

or

 

other

 

vertical

 

surface

 

can

 

be

 

accomplished

 

by

 

using

 

either

 

the

 

supplied

 

peel

and

stick

 

Velcro

 

pads,

 

or

 

by

 

using

 

the

 

integrated

 

keyhole

 

mounts

 

with

 

the

 

supplied

 

wood

 

screws.

  

To

 

use

 

the

 

wood

 

screws:

  

1.

 

Mark

 

the

 

surface

 

using

 

the

 

supplied

 

template

 

2.

 

Screw

 

the

 

#2

 

½”

 

wood

 

screws

 

into

 

the

 

surface

 

at

 

each

 

mark

 

3.

 

Leave

 

a

 

small

 

amount

 

of

 

thread

 

to

 

accommodate

 

the

 

thickness

 

of

 

the

 

TIS

8632

 

case

 

4.

 

Put

 

the

 

large

 

part

 

of

 

the

 

keyhole

 

over

 

the

 

screw

 

head

 

and

 

pull

 

to

 

engage

  

DIN

 

Rail

 

Using

 

the

 

TD

DINR,

 

the

 

TIS

8632

 

can

 

be

 

mounted

 

to

 

a

 

DIN

 

rail.

 

See

 

the

 

TD

DINR

 

user

 

manual

 

for

 

more

 

details

 

on

 

configuration

 

options.

 

Mount

 

the

 

TIS

8632

 

the

 

TD

DINR

 

in

 

the

 

same

 

manner

 

regardless

 

of

 

the

 

initial

 

configuration

 

of

 

the

 

mount

 

itself

 

or

 

the

 

height

 

of

 

top

 

hat

 

DIN

 

rail

 

utilized

 

(35

 

x

 

7.5

 

or

 

35

 

x

 

15mm).

 

The

 

edge

 

mounting

 

solution

 

happens

 

to

 

be

 

shown

 

below.

 

All

 

fasteners

 

necessary

 

for

 

configuration

 

and

 

mounting

 

are

 

included

 

with

 

the

 

TD

DINR.

 

1.

 

Line

 

up

 

key

 

hole

 

on

 

the

 

bottom

 

of

 

the

 

TIS

8632

 

with

 

the

 

studs

 

on

 

the

 

Mounting

 

Bracket

 

and

 

push

 

flat

 

against

 

the

 

plate.

 

2.

 

Slide

 

the

 

TIS

8632

 

forward

 

until

 

it

 

stops.

 

3.

 

Tighten

 

the

 

Retaining

 

Screw

 

until

 

snug.

 

4.

 

Snap

 

the

 

Rail

 

Clips

 

on

 

to

 

the

 

DIN

 

Rail.

 

 

 

Figure

 

4 TIS

8632

 

installation

 

on

 

a

 

TD

DINR

 

Figure

 

3

 

TIS

8632

 

Surface

 

Mount

 

Summary of Contents for TIS-8632

Page 1: ...USER MANUAL 6 Port 10 100 1000 Ethernet Switch TIS 8632...

Page 2: ...Page Intentionally Left Blank...

Page 3: ...et The temperature and the relative humidity of the operating environment must be within the specified limits during operation of the unit Values specified are applicable to the air inlets of the unit...

Page 4: ...isposal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dea...

Page 5: ...rt style supply included or via bussed power supplied through an integrated three pin Phoenix connector Up to three TIS 8632 units can be installed in the optional 1U TDR 01 rack shelf Standard Orderi...

Page 6: ...M Speed 2 Blinks Repeating 100M Speed 1 Blink Repeating 10M Speed SFP Slot x2 This is a standard MSA compliant SFP module slot See section Inserting and Removing SFP Modules These ports operate only a...

Page 7: ...andard DC connection for use with the included DC wall power supply Phoenix Power Connection Secondary power option for the TIS 8632 This is wired in direct parallel with the Circular connector and ha...

Page 8: ...upplied template 2 Screw the 2 wood screws into the surface at each mark 3 Leave a small amount of thread to accommodate the thickness of the TIS 8632 case 4 Put the large part of the keyhole over the...

Page 9: ...adapter provide not just 9 VDC power but a positive earth ground to the modules via 3 position Phoenix locking power connectors Managing all that cabling and fiber can sometimes be quite a chore so a...

Page 10: ...module that you use to disengage the module from a port Handling Warnings SFP Modules are static sensitive To prevent damage from electrostatic discharge ESD it is recommended to attach an ESD preven...

Page 11: ...lasp Open the bail clasp on the SFP Module with your finger in a downward direction Actuator Button Gently press the actuator up or in while pulling the body of the SFP Module to release the SFP Modul...

Page 12: ...Page 10 Applications...

Page 13: ...P MSA designated as INF 8074i This agreement describes a mutually agreed upon standard for the form and function of SFP modules However not all SFPs produced are MSA compliant The MSA provides for a t...

Page 14: ...Page 12 Specifications Figure 7 TIS 8632 Dimensions...

Page 15: ...e 1490 1310 6 25 20 km 1000BASE T SFP RTGTXC 0000 0 Copper n a n a n a 100 m ELECTRICAL SPECIFICATIONS Min Typ Max unit Environmental Storage Temperature C 40 85 C Operating Temperature C 0 50 C Power...

Page 16: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 UMT8632 150512...