Figure 8 TD-6010 Dimensions 

 
 
 

ELECTRICAL SPECIFICATIONS 

 

Min 

Typ 

Max 

unit 

Power Requirement 

Voltage Range 

40 

VDC 

Supply Current, no SFPs 

21 

23 

30 

mA 

Supply Current, max 2 SFP+ 

500 

600 

mA 

 

Environmental 

Storage Temperature 

-40 

85 

°C 

OperatingTemperature 

50 

°C 

Interface 

Full speed USB 2.0 compliant Micro-B Device 

External SFP Interfaces 

Min 

Typ 

Max 

unit 

Data Rate 

155 

12,500 

Mb 

Recommended Jitter 

40 

Psec 

Operating Voltage 

3.3 

 

VDC 

Maximum Current 

500 

mA 

 

Optical Modules 

2 SFP+ MSA (SFF-8431, SFF-8432, SFF-8433) compliant slots, data rate 0 – 12.5 gigabits 

PHYSICAL SPECIFICATIONS 

Case Dimensions 

Length 

Width

 

Height

 

Weight

 

FOI-6010 

Size 4 

4.5 in (114 mm) 

1.453 in (37 mm) 

2.56 in (65 mm) 

2.0 lb (0.9 kg) 

TD-6010 

 

4.5 in (114 mm) 

1.66 in (42 mm) 

2.75 in (70 mm) 

0.4 lb (0.2 kg) 

 

 

 

 2.75

[69.8]

 4.50

[114.3]

 .14

[3.5]

 .11

[2.9]

 1

.6

6

[4

2.

1]

 2

.0

0

[5

0.

8]

 .1

5

[3

.8

]

Summary of Contents for FOI-6010

Page 1: ...USER MANUAL Flexible Interface SFP SFP Transceiver Workbox FOI 6010 TD 6010...

Page 2: ......

Page 3: ...rformed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperature and the relative humidit...

Page 4: ...nformation contained herein Notice The firmware included in this product utilizes the Atmel Software Framework ASF Copyright c 2011 2012 Atmel Corporation All rights reserved Redistribution and use in...

Page 5: ...d streams together so that the different interface protocols can talk the same language Since the fiber based SFPs are the most generic it is usually possible to connect not only two different copper...

Page 6: ...should be retained until the shipment has been checked for completeness and the equipment has been checked mechanically and electrically If the shipment is incomplete if there is mechanical damage or...

Page 7: ...lent to SFP Port A Any SFP installed in this slot will be directly electrically connected to the SFP in Port A Any signals presented in the Receive of Port A will exit on the Transmit of Port B and vi...

Page 8: ...its or internal failure Rear Indicators Connections Figure 2 TD 6010 left and FOI 6010 right Rear Face Circular DC Power Connection DC power entry for the unit On the FOI 6010 this is a Lemo connector...

Page 9: ...can accommodate hot swapped redundant power Alternately the FOI 6010 can be used in a standalone application when paired with a PSQ 4909 for full range AC operation or the PSQ 4920 for 12 48VDC operat...

Page 10: ...dule that you use to disengage the module from a port Handling Warnings SFP Modules are static sensitive To prevent damage from electrostatic discharge ESD it is recommended to attach an ESD preventat...

Page 11: ...he bail clasp on the SFP Module with your finger in a downward direction Actuator Button Gently press the actuator up or in while pulling the body of the SFP Module to release the SFP Module from the...

Page 12: ...SMPTE for broadcast quality digital video transmission Other standards evolved from this original standard defining Enhanced High definition HD 3G SDI 1080p and Ultra High definition UHD or 4K video 2...

Page 13: ...of the internal serial communication pins were reassigned The FOI TD 6010 will accept any of these pinout schemes in any combination For example you can have an MSA compliant SFP in the A position an...

Page 14: ...Specifications Figure 7 FOI 6010 Dimensions 1 45 36 9 2 56 65 1 13 3 2 4 50 114 3 42 10 6 11 2 9...

Page 15: ...ice External SFP Interfaces Min Typ Max unit Data Rate 155 12 500 Mb Recommended Jitter 40 Psec Operating Voltage 3 3 VDC Maximum Current 500 mA Optical Modules 2 SFP MSA SFF 8431 SFF 8432 SFF 8433 co...

Page 16: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 6010UM 1607...

Reviews: