Fiberlink® 3353 Series User’s Manual

Fiberlink® 3353 Series

Figure 1:

Power Connector

DC Input Polarity

9-24 Volts  

AC or DC

 (+) Positive

( - ) Negative

Installation Instructions

The Fiberlink® 3353 Series of fiber optic transmission systems are ready for  

immediate use and do not require any special tools. However, an Optical Power Meter, 

such as the Fiberlink® 6615, can be useful in determining optical loss budgets during your 

systems design and maintenance. 

Fiberlink® 3353 will operate with the Fiberlink 3350, Fiberlink 3360, Fiberlink 3370, Fiberlink 

3380, Scan Do® HD, Fiberlink Matrix and SMPTE 297-2006 compliant optical tranmission 

units. The following procedure presumes you have followed the instructions for installing 

your optical transmitter unit. 

 

The following instructions describe the typical installation procedure:

1)  Connect the fiber optic cable to the optical input of the receiver unit.
2)  Connect the video output cable (HDMI) to the video output HDMI connector on  
 

the receiver unit. 

3)   Optionally connect any audio cables and using the channel pair rotary selector,  
 

choose your desired audio output channel. Audio is also embedded on the  

 

HDMI cable.

4)  Terminate any unused BNC output connector at 75 Ohms.
5)  Connect the Universal Power Supply to the transmitter and receiver units.  
 

Please refer to figure 1.

6)   When power is applied, the green POWER LED should illuminate, indicating the  
 

presence of operating power. The 3G/HD/SD RATE LED will give an indication as  

 

described in the Indicator LED’s and Alarm Circuitry section of this manual.

7)  The system should now be operational.

Installation Instructions

The transmitting element in the Fiberlink® 3350, 3360, 3370 
and 3380 transmitter units contains a solid state Laser Diode 
located in the optical connector. This device emits invisible 
infrared electromagnetic radiation which can be harmful 
to human eyes. The radiation from this optical connector, if 
viewed at close range with no fiber optic cable connected to 
the optical connector, may be sufficient intensity to cause 
instantaneous damage to the retina of the eye. Direct 
viewing of this radiation should be avoided at all times!

Summary of Contents for 3353 Series

Page 1: ...3 1638 info commspecial com Asia Communications Specialties Pte Ltd 100 Beach Road 22 09 Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 csiasia commspecial com commspecial com Communica...

Page 2: ...echnical Specifications Model Part Number Specifications 4 General Specifications 4 Installation Instructions 6 Audio Pair Selection 7 Indicator LEDs 7 Application Diagrams 8 Operating Pointers 9 Trou...

Page 3: ...also provides immunity to video pathological signals over the entire link budget and operating temperature range Features Convert 3G HD SD SDI with embedded audio to HDMI with audio pair selection Sup...

Page 4: ...MPTE 297 2006 Labeling PC ABCD 1310 1550 Connector LC receptacle PC polish or ST Wavelength 1100 1620 nm Minimum Input Sensitivity 17 dBm at 2 97 Gbps 20 dBm at 1 485 Gbps 23 dBm at 270 Mbps Maximum I...

Page 5: ...rom audio embedded within SDI signal in accordance with SMPTE standards 3G HD SD SDI Output Signal Level 800mV 10 DC Offset 0V 0 5V Rise Fall Time 135 ps at 2 97 Gbps per SMPTE 424M 270 ps at 1 485 Gb...

Page 6: ...on the receiver unit 3 Optionally connect any audio cables and using the channel pair rotary selector choose your desired audio output channel Audio is also embedded on the HDMI cable 4 Terminate any...

Page 7: ...rate lock at 270 Mbps Alarm On Loss of optical signal Note The 3G HD and SD LEDs indicators are off when a non standard signal is applied Rotary Switch Positions Position Function 0 Will mute the audi...

Page 8: ...Source 3353 Rx 3355 Rx 3353 Rx 3355 Rx Fiber Cable Fiber Cable Fiber Cable Fiber Cable Fiber Cable 3353 Rx Fiber Cable Fiber Cable Scan Do HD DVI or Analog RGB to 3G HD SD SDI Scan Converter Multicha...

Page 9: ...vide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal...

Page 10: ...light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink...

Page 11: ...cluding free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipme...

Page 12: ...Power Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It ca...

Page 13: ...s a stand alone 3G HD SD SDI optical link Previously serialized data is left intact throughout the entire transmission process and the 3360 Series is immune to pathological signals over the entire bud...

Page 14: ...Page 14 Fiberlink 3353 Series User s Manual Fiberlink 3353 Series...

Page 15: ...Page 15 Fiberlink 3353 Series User s Manual Fiberlink 3353 Series...

Page 16: ...6396 0138 csiasia commspecial com commspecial com 2010 Communications Specialties Inc All Rights Reserved Fiberlink and the starburst logo are registered trademarks of Communications Specialties Inc...

Reviews: