background image

 

ii 

 

 

 

         

Instruction for your safety

         

 

Please be sure to pay attention to all cautions and warnings 

before using the system. 

Incorrect usage could lead to an electrical shock, damage to 

the system or a fire hazard. 

 

Warning                                                                                                                       

 Do not modify, disassemble or remove the cover. These actions could cause electrical 

shock. We shall never be responsible for any problems caused by your reconstruction or 

modification. 

 Do not touch the internal components. They may have high voltage or high temperature. 

You may get electrical shock or burnt. 

 When the system is operating, keep your hands and face away from it. Otherwise, you 

may get injured by an accident. 

 

Caution                                                                                                                         

 Please read catalogue and instruction manual carefully before use. 

 Use  the  products  within  the  specified  input  voltage,  temperature  and  humidity.  Use  of 

products in non-specified condition may damage the product. 

 Connect the frame ground terminal to the ground terminal of the device for safety. Use 

of the products without ground connection may cause an electrical shock. 

 Do  not  use  the  product  in  the  environment  with  strong  electromagnetic  field,  gas  and 

conductive substances. 

Summary of Contents for GZF850-VH

Page 1: ...FiberHome SM GZF850 VH GZF850 VH Repeater B40Y02JW02YF User Manual Nov 2010...

Page 2: ...oes not assume any liability arising out of the application or use any product or circuit described herein No part of this documentation may be excerpted reproduced translated annotated or duplicated...

Page 3: ...age or high temperature You may get electrical shock or burnt When the system is operating keep your hands and face away from it Otherwise you may get injured by an accident Caution Please read catalo...

Page 4: ...ybrid mobile communications network It receives and amplifies forward and reverse Radio Frequency RF signal to extend the coverage of base station This user manual covers the system frame technical sp...

Page 5: ...ATIONS 6 3 INSTALLATION 8 3 1 INSTALLATION FLOW 8 3 2 PROJECT PREPARATIONS 9 3 2 1 User s Cooperation 9 3 2 2 On site Survey 9 3 2 3 Installation Tools 9 3 2 4 Technical Documentation 10 3 3 INSTALLAT...

Page 6: ...llowing figure shows the system frame of GZF850 VH repeater Power Supply RF signal flow Monitoring signal flow Antenna Modem Monitor Battery Door Sensor BTS Reverse Forward LNA PA BCS BCS PD PD D L X...

Page 7: ...a and query data etc Reliability Industrial level components are used which can sustain a temperature range of 25 C 55 C for outdoor repeater only so that the product can work reliably in a wide range...

Page 8: ...it is suggested to install Window2000 XP Window2003 It is necessary to install DirectX 8 0 or above for Window98 ME There is no special requirement for configuring communication server 1 4 Technical...

Page 9: ...4 2 Other Specification MECHANICAL SPECIFICATION Dimensions Approx 513 462 232mm Weight Approx 17 4kg Ingress Protection Class IP65 ENVIRONMENT SPECIFICATION Operating Temperature 25 55 Humidity 95 O...

Page 10: ...User Manual 5 1 6 Structure 1 6 1 Figure of Repeater 1 6 2 Figure of Side Panel...

Page 11: ...using a small Yagi antenna or Logarithm period antenna low power repeater amplifies the signal and combines the indoor distribution system which quickly improve the signal in shadowy or blind zones C...

Page 12: ...User Manual 7 Indoor Distribute System...

Page 13: ...Unpacking goods checking Antenna feeder installation Repeater installation Grounding AC power connection Fig 3 1 the general workflow of the repeater To ensure safety during the installation make sur...

Page 14: ...tallation the installation technicians should consult with the project manager of the user and learn whether the installation site is ready for equipment installation Specifically they should survey s...

Page 15: ...allation 1 220V AC power is available 2 A grounding bar is available nearby 3 There are appropriate buildings iron towers or high poles to mount the donor antenna and service antenna 3 3 2 Recommended...

Page 16: ...pection Open the packing box if it is intact Handle with care to avoid damaging anything After the packing box is opened check whether the goods inside match the packing list and whether the packing l...

Page 17: ...er is attached with such installation fittings as installation board and fixing pieces The chassis of the repeater can be mounted either on the wall or on a high pole The bottom of the equipment is us...

Page 18: ...rs It is applicable in the windows2000 and windows XP operation system 4 1 Configure the Software The following steps are the process of connecting PC or laptop to the repeater on the site Be sure the...

Page 19: ...nual 14 Step1 Choose the Serial which connect with testing equipment then Click open serial We need RS232 cable to connect the repeater with the PC or laptop Port 2 Port 1 1 2 3 4 5 6 7 8 9 1 2 3 4 5...

Page 20: ...and pin 3 of the RS232 cable are crossing connected and two pins 5 of the two tie ins are connected directly Pins left are not connected Step 2 Click on line to connect with testing equipment Step 3...

Page 21: ...e to File View and then click file 850 VH that is related to testing equipment Then Click Query to ensure successful connection between the PC and testing equipment Click Set Parameter to keep the RF...

Page 22: ...and Work Channel 3 It displays the start frequency ARFCN of the second adjustable band Work Channel 4 It displays the stop frequency ARFCN of the second adjustable band Please click Read before Set No...

Reviews: