5 Card
Table 5-10
Panel of the MSS1/MSS2/MSS3 Card
Indicator/Interface/But-
ton
Description
ACT
Operating indicator (green)
Blinking quickly: The card is operating normally.
ON or OFF: The card is not operating normally.
(ON generally means a poor communication between the card and
the OTNM2000.)
UA
Critical alarm indicator (red)
OFF: The card does not have any critical or major alarm, or all the
critical or major alarms are filtered.
ON: The card has a critical or major alarm.
NUA
Non-critical alarm indicator (yellow)
OFF: The card does not have any minor alarm, or all the minor
alarms are filtered.
ON: The card has a minor alarm.
GE / FE1 to GE / FE8
Inputs or outputs FE / GE signals.
Interface type: LC
Applicable Slot
The MSS1/MSS2/MSS3 card can be inserted to slot 02 or 03.
Technical Parameters
Table 5-11 lists mechanical parameters and power consumption of the MSS1/
MSS2/MSS3 card. Table 5-12 and Table 5-13 list specifications of the GE and FE
optical interfaces.
Table 5-11
Technical Specifications of the MSS1/MSS2/MSS3 Card
Card
Weight (kg)
Dimensions (H W D)
(mm)
Power Consumption (W)
MSS1
0.5
20 192 198
8.5
MSS2
0.5
20 192 198
7
MSS3
0.5
20 192 198
6
Table 5-12
GE Optical Interface Specifications of the MSS1/MSS2/MSS3 Card
Item
Specification
Optical interface type
1000BAS-
E-SX
1000BASE-
LX
1000BASE-
VX
1000BAS-
E-ZX1
1000BASE-
ZX2
Source type
MLM
MLM
SLM
SLM
SLM
Version: A
5-17