Fiber Tronix FT-FRXID-RM-SCAPC Operation Manual Download Page 4

 

4

Specifications 

NO. Item  Unit 

Description 

Remark 

Optical Input   

Optical Input Wavelength 

nm 

1200

1600 

 

Optical Input Power 

dBm 

-8

+2 

 

Optical Connector Type 

 

FC/APC or SC/APC 

 

4 Optical 

Output 

Loss  dB 

45  

Backup Receiver Switching Operating 

Point 

dBm 

Optional

RF Output   

Frequency Range 

MHz 

47

860/1000 

 

Flatness dB 

±0.75 (output 1

2) 

 

8 RF 

Output 

Test  dB  -20±1 

 

9 Output 

Level 

dBmV

36  

10 

RF Output Slope Adjustment 

dB 

0

18dB 

factory preset to 

0dB

 

 

11 RF 

Impedance 

 75   

12 

Return Loss 

dB 

16(47

860MHz) 

 

13 

Optical Power Monitoring Point

V/mw 1 

 

14 

CNR dB 

51

system indicators

 

2

 

15 

CSO dB 

-61

system indicators

 

16 

CTB dB 

-65

system indicators

 

17 

Power V 

220,+10%/-20% 

 

18 

Operating Temperature 

 

10

~+

50 

 

 

 

 

 

Installation

 

1. Unpacking 

Open box and inspect for damages. Locate the optical receiver, power cord, and user’s 

manual. 

 

2. Mounting 

The 

FT-FRXID-RM-SCAPC

 is a rack mountable 1RU device. To ensure sufficient 

cooling, it is recommended to leave 1.75” spacing above and below device.   

 

3. Making Connections 

Plug the power cord into the power supply socket and switch the power on. 

 

All optical connections to the 

FT-FRXID-RM-

SCAPC are SC/APC connections.  Be 

sure to clean all optical connectors before connection.    Connect SC/APC connector to 

“OPT In” on the rear of the transmitter. 

Reviews: