background image

Application Note

SecurLAN

®

 

Optical Cutoff Switch

Installation

Rev. A

SummAry
Connected to the SecurLAN system, the Optical Cutoff Switch op-

tion enables the system or the operator to take protective action in 

the event an intrusion attempt is detected at the physical level of a 

network’s infrastructure.  unlike older versions of the hardware, the 

new Optical Cutoff Switch is not only capable of disrupting the flow of 

data through the compromised cable, but certain configurations of the 

switch are also capable of re-routing data to a secured cable. 

I

ntroductIon

The SecurLAN

®

 Optical Cutoff Switch is an option that enables the Secur-

LAN system to take protective action in the event an intrusion attempt is 

detected at a protected network data cable (a network configuration known 

as a Protected Distribution System or PDS).  Depending upon its configu

-

ration, the Optical Cutoff Switch is able to either halt the flow of data or 

re-route it to another cable.

Figure 1 - 

The SecurLAN System Block Diagram

Summary of Contents for SecurLAN

Page 1: ...pting the flow of data through the compromised cable but certain configurations of the switch are also capable of re routing data to a secured cable Introduction The SecurLAN Optical Cutoff Switch is...

Page 2: ...ed Figure 2 The Optical Cutoff Switch The Optical Cutoff Switch has 3 general configurations A 1x1 switch with one pair of direct input to output ports A 2x2 switch with a dual pair of direct input to...

Page 3: ...low 6 VDC the normally closed Optical Cutoff Switch opens disrupting the optical data flow Input voltage over the 15 volt limit damages the switch Note If the 15 volt maximum limit is exceeded the sta...

Page 4: ...the Input pin on the rear panel of the Optical Cutoff Switch Placing a ground on this pin shunts power away from the internal optical switch causing the internal switch to open and halt the flow of d...

Page 5: ...er supply to Pin 1 of the Optical Cutoff Switch 2 Connect the negative lead of the power supply to Pin 2 of the Optical Cutoff Switch 3 Select a relay on the ORM to use for activating the Optical Cuto...

Page 6: ...4 Optical Cutoff Switch Input Truth Table The maximum wiring distance between the power supply and the Optical Cutoff Switch is 15 meters 50 feet assuming 22 AWG 8 conductor shielded cable is used On...

Page 7: ...SecurLAN Optical Cutoff Switch Installation Application Note Figure 4 Optical Cutoff Switch Wiring Diagram...

Page 8: ...sing the Optical Cutoff Switch option with the SecurLAN system please contact Fiber SenSys sales or technical support team directly at 1 503 692 4430 or by email at info fibersensys com 2925 NW Alocle...