background image

Fiber Options

i

GENERAL  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1  INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.1  INSTALLATION CONSIDERATIONS.  . . . . . . . . . . . .1 
1.2  STANDALONE MODULES . . . . . . . . . . . . . . . . . . . .1
1.3  RACK CARDS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.3.1  515R1 AND 517R1 CARD CAGES . . . . . . . . . . .1
1.3.2  501R ENCLOSURES  . . . . . . . . . . . . . . . . . . . . .1

2 SIGNAL CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . . .2
3 OPTICAL CONNECTIONS  . . . . . . . . . . . . . . . . . . . . . . .2
4 ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . .2

4.1 RACKMOUNT CARDS  . . . . . . . . . . . . . . . . . . . . . . .2
4.2 STANDALONE MODULES  . . . . . . . . . . . . . . . . . . . .2

5 TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . . . . . . . . .2
6 CONTACTING FIBER OPTIONS  . . . . . . . . . . . . . . . . . .2
7 SHIPPING AND PACKING  . . . . . . . . . . . . . . . . . . . . . . .2
8 RETURNS TO FIBER OPTIONS  . . . . . . . . . . . . . . . . . .2

Contents

Figures & Tables

FIGURE 1: STANDALONE TRANSMITTER  . . . . . . . . . . . .ii
FIGURE 2: 501R ENCLOSURE  . . . . . . . . . . . . . . . . . . . .ii
FIGURE 3: SYSTEM DIAGRAM  . . . . . . . . . . . . . . . . . . . .1
FIGURE 4: S703V  RACK CARD . . . . . . . . . . . . . . . . . . . .3
FIGURE 5: RACK CARD FRONT BEZELS  . . . . . . . . . . . .3
FIGURE 6: RACK CARD CONNECTIONS . . . . . . . . . . . . .3

TABLE 1: POWER CONNECTION 

STANDALONE MODULE   . . . . . . . . . . . . . . . . . . . .ii

TABLE 2: POWER CONNECTION

502R ENCLOSURE   . . . . . . . . . . . . . . . . . . . . . . . .ii

TABLE 3: TRANSMITTER LED DIAGNOSTIC  . . . . . . . . . .

INDICATORS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

TABLE 4: RECEIVER LED DIAGNOSTIC  . . . . . . . . . . . . .

INDICATORS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Summary of Contents for S703V

Page 1: ...Instruction Manual light years ahead S703V S7703V TWO CHANNEL VIDEO MULTIPLEXERS...

Page 2: ...vironment Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to take whatev er means may be necessary to correct the interference...

Page 3: ...S 2 5 TROUBLESHOOTING 2 6 CONTACTING FIBER OPTIONS 2 7 SHIPPING AND PACKING 2 8 RETURNS TO FIBER OPTIONS 2 Contents Figures Tables FIGURE 1 STANDALONE TRANSMITTER ii FIGURE 2 501R ENCLOSURE ii FIGURE...

Page 4: ...tion Manual ii TABLE 2 POWER CONNECTION 501R ENCLOSURE TABLE 1 POWER CONNECTION STANDALONE TRANSMITTER FIGURE 1 STANDALONE TRANSMITTER FIGURE 2 501R ENCLOSURE PIN CONNECTION 1 12 16 VAC 12 16 VDC 2 DC...

Page 5: ...LONE MODULES Determine where the module is to be installed and ensure that there is adequate space at both ends for making the various cable connections and for reading the diagnostic LEDs Standalone...

Page 6: ...wer supply is not connected to any power source and strip approximately 0 25 in 6 mm of insulation from the ends of the cable 3 Taking care to observe correct polarization of the cable see table 1 for...

Page 7: ...4 S703V RACK CARD VIDEO IN VIDEO IN 703 T VIDEO IN 7703 T VIDEO IN VIDEO OUT 703 R LVL LOSS VIDEO OUT VIDEO OUT 7703 R LVL LOSS VIDEO OUT FIGURE 5 RACK CARD FRONT BEZELS TRANSMITTER LEFT AND RECEIVER...

Page 8: ...33 01 60 86 54 53 Fax 33 01 60 86 86 04 Germany Tel 49 700 34237678 Fax 49 36256 21991 Hong Kong Tel 852 2907 8108 Fax 852 2142 5063 Latin America Tel 800 342 3748 Fax 877 342 3732 TABLE 4 RECEIVER L...