Behavior within the Z-Wave network

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an 

existing wireless network to communicate with the devices of this network. This process is called Inclusion

Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the 

primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion 

mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or 

exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave 

the network. Leaving the network - i.e. being excluded - sets the device back to factory default.

If the device already belongs to a network, follow the exclusion process before including it in your network. 

Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to 

be reset first.

Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into 

inclusion mode  tripple click the button of the device or the push-button B located inside the housing 

of the switch relay to include the device. A green blinking of LED will indicate successfull inclusion that 

will be turned off shortly afterwards. The device is excluded by tripple click on one of the buttons when 

the controller is in exclusion mode.

Operating the device

The switch insert is able to switch two different electrical loads. The actuator can directly be operated by a 

local switching paddle. If the switch is a conventional button, every button impulse will connect the switch 

ON or OFF. Using a switching paddle instead of a button the operation is the same with the exception that 

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Summary of Contents for FGS-221

Page 1: ...rt homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act...

Page 2: ...vailable space depends on the size of the traditional switch the dimensions of the wall box and the amount of additional cabling placed in this box This device is designed for a 3 wire system and need...

Page 3: ...connected to the insert contact I The electrical load is then connected to the other pole of the 230 V power supply or with the second pole of the additional power supply The switch can be operated lo...

Page 4: ...ert as shown in the schematics If a bistable switch is connected it has to stay connected until the switch is included into the Z Wave network It is also possible to use a double switch for local cont...

Page 5: ...etwork Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Blinking red green LED indicates that the device is in factory re...

Page 6: ...ion group will receive a common wireless command Association Groups 1 external Switch No 1 max nodes in group 16 2 external Switch No 2 max nodes in group 16 3 max nodes in group 1 Configuration Param...

Page 7: ...200 Commands Sent to Association Group 1 Parameter Number 6 Parameter Size 1 Defines what status changes cause sending out a wireless command Zu allow double click function parameter 15 needs to be tu...

Page 8: ...power down Parameter Number 16 Parameter Size 1 The device will or will not return to the last switch state after a power down Value Description 0 not return to previous state Default 1 return to pre...

Page 9: ...in case of alarm 2 Enable on Alarm will switch on in case of alarm 3 Flashing on Alarm will switch on and off periodically for 10 minutes Default Temperature Alarm Set Relay 1 Parameter Number 33 Par...

Page 10: ...ll switch off in case of alarm 2 Enable on Alarm will switch on in case of alarm Default 3 Flashing on Alarm will switch on and off periodically for 10 minutes Smoke Alarm Set Relay 2 Parameter Number...

Page 11: ...utes Command Classes Supported Command Classes Basic version 1 No Operation version 0 Binary Switch version 1 Version version 1 All Switch version 1 Multi Channel version 2 Multi Channel Association v...

Page 12: ...f bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled de...

Reviews: