FIBARO FGRGBWM-441 Operating Manual Download Page 2

XIII Advanced configuration

GENERAL:

1. ALL ON / ALL OFF function activation

Default setting: 

255

0

 - ALL ON inactive, ALL OFF inactive

1

 - ALL ON inactive, ALL OFF active

- ALL ON active, ALL OFF inactive

255

 - ALL ON active, ALL OFF active

Parameter size: 

1 [byte]

6. Associations command class choice

Default setting: 

0

0

 - NORMAL (DIMMER) - BASIC SET/SWITCH_MULTILEVEL_-

START/STOP

1

 - NORMAL (RGBW) - COLOR_CONTROL_SET/STAR-

T/STOP_STATE_CHANGE

2

 - NORMAL (RGBW) - COLOR_CONTROL_SET

3

 - BRIGHTNESS - BASIC SET/SWITCH_MULTILEVEL_STAR-

T/STOP

4

 - RAINBOW (RGBW) - COLOR_CONTROL_SET

Parameter size: 

1 [byte]

IN/OUT:
8. Outputs state change mode

Default setting:

 0

0 - 

MODE1 (related parameters: 9-step value, 10-time between 

steps)

1

 - MODE2 (related parameters: 11-time to change value, relevant 

for RGB/RGBW)

Parameter size: 

1 [byte]

MODE1
Example: change saturation level from 0% to 99%

Parameter  9: 

Step = 5

Parameter 10:

 Time between steps: 10ms

9. Step value (relevant for MODE1)

Default setting: 

1

Available settings: 

1 - 255

Parameter size: 

1[byte]

10. Time between steps (relevant for MODE1)

Default setting: 

10 (10ms)

0 - 

immediate change of state

1-60000

 - (

1-60000 ms

)

MODE2
Example: change saturation level from 0% to 99%

Parameter 11: 

time for changing from start to end value = 500sec

11. Time for changing from start to end value

Default setting: 

67 (3s)

0

 - immediate change

1-63

 - 20-126- [ms] value*20ms

65-127

 - 1-63 [s] [value-64]*1s

129-191

 - 10-630[s] [value-128]*10s

193-255

 - 1-63[min] [value-192]*1min

Parameter size: 

1[byte]

12. Maximum brightening level

Default setting: 

255

Available settings: 

3-255

Parameter size: 

1[byte]

13.  Minimum dim level

Default setting: 2

Available settings: 3-255

Parameter size: 1[byte]

14. Inputs / Outputs configuration - relevant for main 

      controllers other than Home Center 2 only

Default setting: 

4369

 Controlled device: RGBW, toggle switch 

inputs (NORMAL MODE)

Each 4bit refer to given IN/OUT (channel) settings

Note

The maximum leven cannot be lower than 

minimum level.

i

Channel 1

(4 bit)

Channel 2

(4 bit)

Channel 3

(4 bit)

Channel 4

(4 bit)

0000

0000

0000

0000

....

....

....

....

1111

1111

1111

1111

If RGB/RGBW mode is chosen, settings for all 4 channels are 

identical. Settings marked with X are forbidden and cannot be sent 

to the module. 

Settings available for single channel

16. Memorize device status at power cut. Device will be set to 

status memorized before power cut.

Default setting: 

1

- device does not memorize its status at the power cut. Load is 

disconnected.

1

 - device memorizes its status at the power cut. Load will be set 

to the status from before power cut (parameters, current outputs 

status, energy)

Parameter size: 

1[byte]

ALARM:
30. Alarm of any type (general alarm, flood alarm, smoke 

alarm: CO, CO2, temperature alarm).

Default setting: 0

0 - INACTIVE - the device doesn't respond to alarm frames

1 - ALARM ON - the device turns on once alarm is detected (all 

channels set to 99%)

2 - ALARM OFF - the device turns off once alarm is detected (all 

channels set to 0%)

3 - ALARM PROGRAM - alarm sequence turns on (program 

selected in parameter 38)

Parameter size: 1[byte]

38. Alarm sequence program

Default setting: 

10

1 - 10

 (1-10 specifies alarm program number)

Parameter size: 

1[byte]

39. Active PROGRAM alarm time

Default setting: 

600

1-65534

 (1s-65534s)

Parameter size: 

2[byte]

REPORTS:
42. Command class reporting Outputs status change

Default setting: 0

0

 - reporting as a result of inputs and controllers actions (SWITCH 

MULTILEVEL)

1

 - reporting as a result inputs actions (SWITCH MULTILEVEL)

2

 - reporting as a result of inputs actions (COLOR CONTROL)

Parameter size: 

1[byte]

43. Reporting 0-10v analog inputs change threshold. 

Parameter defines a value by which input voltage must change in 

order to be reported to the main controller. New value is calculated 

based on last reported value: 

Default setting: 

5 (0,5V) 

1-100

 - (0,1 - 10V)

Parameter size: 

1[byte]

44. Power load reporting frequency 

(if last reported value differs 

from the current value). Reports will also be sent in case of polling.

Default setting: 

30 (30s)

1 - 65534

 (1s-65534s) - time between reports,

0

 - reports are not sent. Reports will only be sent in case of polling 

or at turning OFF the device.

Parameter size: 

2[byte]

45. Reporting changes in energy consumed by controlled 

devices. 

New, reported energy value is calculated based on last 

reported value. 

Default setting: 

10 (0,1 kWh)

1 - 254

 (0,01kWh - 2,54kWh)

0

 - changes in consumed energy will not be reported. Reports will 

be sent only in case of polling.

Parameter size: 

1[byte]

OTHER:
71. Response to BRIGHTNESS set to 0%

Default setting: 

1

0

 - illumination colour set to white (all channels controlled together)

1

 - last set colour is memorized

Parameter size: 

1[byte]

72.  Starting predefined program when device set to work in 

RGB/RGBW mode (parameter 14) - relevant for main 

controllers other than Home Center 2 only.

Default setting: 

1

1-10

 animation program number

Parameter size: 

1[byte]

73. Triple click action

Default setting: 

0

0

 - NODE INFO control frame is sent,

1

 - starting favourite program

Parameter size: 

1[byte]

1. The Guarantee is provided by FIBAR GROUP Sp. z o.o. 

(hereinafter "Manufacturer"), based in Poznan, ul. Lotnicza 1; 60-421 

Poznan, entered in the register of the National  Court Register kept 

by  the  District  Court  in  Poznań,  VIII  Economic  Department  of  the 

National  Court  Register,  no.  370151,  NIP  7811858097,  REGON: 

301595664.

2. The Manufacturer is responsible for equipment malfunction 

resulting from physical defects (manufacturing or material) of the 

Device for 12 months from the date of its purchasing.
3.  During the Guarantee period, the Manufacturer shall remove any 

defects, free of charge, by repairing or replacing (at the sole 

discretion of the Manufacturer) any defective components of the 

Device with new or regenerated components, that are free of 

defects. When the repair impossible, the Manufacturer reserves the 

right to replace the device with a new or regenerated one, which shall 

be free of any defects and its condition shall not be worse than the 

original device owned by the Customer.
4.  In special cases, when the device cannot be replaced with the 

device of the same type (e.g. the device is no longer available in the 

commercial offer), the Manufacturer may replace it with a different 

device having technical parameters similar to the faulty one. Such 

activity shall be considered as fulfilling the obligations of the 

Manufacturer. The Manufacturer shall not refund money paid for the 

device.

5.  The holder of a valid guarantee shall submit a guarantee claim

 

through the guarantee service. Remember: before you submit a 

guarantee claim, contact our technical support using telephone or 

e-mail. More than 50% of operational problems is resolved remotely, 

saving time and money spent to initiating guarantee procedure. If 

remote support is insufficient, the Customer shall fill the guarantee 

claim form (using our website - www.fibargroup.com) in order to 

obtain claim authorization.

When the guarantee claim form is submitted correctly, the Customer 

shall receive the claim confirmation with an unique number (Return 

Merchandise Authorization -RMA).
6.  The claim may be also submitted by telephone. In this case, the 

call is recorded and the Customer shall be informed about it by a 

consultant before submitting the claim. Immediately after submitting 

the claim, the consultant shall provide the Customer with the claim 

number (RMA-number).
7. When the guarantee claim form is submitted correctly, a 

representative of the Authorised Guarantee Service (hereinafter as 

"AGS") shall contact the Customer. 
8.  Defects revealed within the guarantee period shall be removed 

not later than 30 days from the date of delivering the Device to AGS. 

The guarantee period shall be extended by the time in which the 

Device was kept by AGS.
9. The faulty device shall be provided by the Customer with complete 

standard equipment and documents proving its purchase.

XIV Guarantee

10. Parts replaced under the guarantee are the property of the 

Manufacturer. The guarantee for all parts replaced in the guarantee 

process shall be equal to the guarantee period of the original device. 

The guarantee period of the replaced part shall not be extended.
11. Costs of delivering the faulty device shall be borne by the 

Customer. For unjustified service calls, the Service may charge the 

Customer with travel expenses and handling costs related to the 

case. 
12.  AGS shall not accept a complaint claim only when: 

• the Device was misused or the manual was not observed,

• the Device was provided by the Customer incomplete, without 

accessories or nameplate, 

• it was determined that the fault was caused by other reasons than 

a material or manufacturing defect of the Device  

• the guarantee document is not valid or there is no proof of 

purchase, 
13. The Manufacturer shall not be liable for damages to property 

caused by defective device. The Manufacturer shall not be liable for 

indirect, incidental, special, consequential or punitive damages, or 

for any damages, including, inter alia, loss of profits, savings, data, 

loss of benefits, claims by third parties and any property damage or 

personal injuries arising from or related to the use of the Device.
14. The guarantee shall not cover:

• mechanical damages (cracks, fractures, cuts, abrasions, physical 

deformations caused by impact, falling or dropping the device or 

other object, improper use or not observing the operating manual);

• damages resulting from external causes, e.g.: flood, storm, fire, 

lightning, natural disasters, earthquakes, war, civil disturbance, force 

majeure, unforeseen accidents, theft, water damage, liquid leakage, 

battery spill, weather conditions, sunlight, sand, moisture, high or low 

temperature, air pollution;

• damages caused by malfunctioning software, attack of a computer 

virus, or by failure to update the software as recommended by the 

Manufacturer;

• damages resulting from: surges in the power and/or telecommuni-

cation network, improper connection to the grid in a manner 

inconsistent with the operating manual, or from connecting other 

devices not recommended by the Manufacturer.

• damages caused by operating or storing the device in extremely 

adverse conditions, i.e. high humidity, dust, too low (freezing) or too 

high ambient temperature. Detailed permissible conditions for 

operating the Device are defined in the operating manual; 

• damages caused by using accessories not recommended by the 

Manufacturer

• damages caused by faulty electrical installation of the Customer, 

including the use of incorrect fuses;

• damages caused by Customer's failure to provide maintenance and 

servicing activities defined in the operating manual;

• damages resulting from the use of spurious spare parts or 

accessories improper for given model, repairing and introducing 

alterations by unauthorized persons;

• defects caused by operating faulty Device or accessories.

15. The  scope  of  the  guarantee  repairs  shall  not  include  periodic 

maintenance and inspections, in particular cleaning, adjustments, 

operational checks, correction of errors or parameter programming 

and other activities that should be performed by the user (Buyer). 

The guarantee shall not cover natural wear and tear of the Device 

and its components listed in the operating manual and in technical 

documentation as such elements have a defined operational life.
16. If a defect is not covered by the guarantee, the Manufacturer 

reserves the right to remove such defect at its sole discretion, 

repairing the damaged or destroyed parts or providing components 

necessary for repair or replacement. 
17. This guarantee shall not exclude, limit or suspend the Customer 

rights when the provided product is inconsistent with the purchase 

agreement.

MSB

LSB Controlled

device

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

(RGBW)

X

(RGBW)

MOMENTARY

(NORMAL MODE)

(RGBW)

MOMENTARY

(BRIGHTNESS MODE)

(RGBW)

MOMENTARY

(RAINBOW MODE)

(RGBW)

TOGGLE

(NORMAL MODE)

(RGBW)

TOGGLE

(BRIGHTNESS MODE)

(RGBW)

TOGGLE W. MEMORY

(NORMAL MODE)

(RGBW)

TOGGLE W. MEMORY

(BRIGHTNESS MODE)

(IN)

ANALOG 0-10V

(SENSOR)

(OUT)

MOMENTARY

(NORMAL MODE)

(OUT)

X

X

(OUT)

(OUT)

TOGGLE

(NORMAL MODE)

(OUT)

X

(OUT)

TOGGLE W/MEMORY

(NORMAL MODE)

0

0

0

0

0

0

0

1

0

0

1

0

0

0

1

1

0

1

0

0

0

1

0

1

0

1

1

0

0

1

1

1

1

0

0

0

1

0

0

1

1

0

1

0

1

0

1

1

1

1

0

0

1

1

0

1

1

1

1

0

1

1

1

1

(OUT)

X

This Device may be used with all devices 

certified with Z-Wave certificate and should be 

compatible with such devices produced by 

other manufacturers. 

Any device compatible with Z-Wave may be added 

to Fibaro system. 

i

FIBARGROUP 

FIBARO

In case of any technical questions contact customer service centre 

in your country.

www.fibargroup.com

Fig. 6- Terminals description

Fig. 7 - Connecting halogen lighting

Fig. 8 - 0-10 V sensors wiring diagram

Fig. 9 - RGBW strip wiring diagram

Fig 10. - RGBW strip with 0-10 V potentiometer wiring diagram

NOTES FOR THE DIAGRAM

12/24VDC - power supply signal 

GND - power supply ground signal

IN1 - potential free / 0-10V input 1 

IN2 - potential free / 0-10V input 2

IN3 - potential free / 0-10V input 3

IN4 - potential free / 0-10V input 4

R - output assigned to IN1 

G - output assigned to IN2

B - output assigned to IN3

W - output assigned to IN4

Note!

Parameter 14 recommended 

settings, for controllers other than 

Home Center 2, are available under 

the following link:

http://manual.rgbw.fibaro.co.uk/

ras-rgbw-controller-en.pdf

Locate the antenna as far from metal elements as 

possible (connecting wires, bracket rings, etc.) in 

order to  prevent interferences. 

i

Metal surfaces in the direct vicinity of the antenna 

(e.g. flush mounted metal boxes, metal door frames) 

may impair signal reception! 

i

TIPS FOR ARRANGING THE ANTENNA:

Do not cut or shorten the antenna - its length is 

perfectly matched to the band in which the system 

operates

i

Input type:

ANALOG - 

sensor with analog, 0-10V interface. Impossible to 

control from main controllers interface.

MOMENTARY

 - momentary switch,

TOGGLE - 

toggle switch,

TOGGLE W/MEMORY

 - toggle switch (ON active for closing 

switch terminals; OFF active for opening switch terminals)

Input operating mode (controlled with switch keys):

NORMAL - 

each given switch key assigned to one output 

channel,

BRIGHTNESS - 

all of the channels are controlled together,

RAINBOW - 

transition through all colours spectrum (operates on 

3 RGB channels only)

Parameter size: 

2[byte]

FIBARO

RGBW

CONTROLLER

B

IN1

GND

IN2

IN3

IN4

R

G

B

12/24VDC

W

B

12/24 VDC

Adapter

Wind

Sensor

Temperature

Sensor

Humidity

Sensor

Light

Sensor

12V
GND
IN1
IN2
IN3
IN4
Red
Green
Blue
White

FIBARO

RGBW

CONTROLLER

FIBARO

RGBW

CONTROLLER

B

12/24 VDC

Adapter

230V AC

12V
GND
IN1
IN2
IN3
IN4
Red
Green
Blue
White

FIBARO

RGBW

CONTROLLER

B

12/24 VDC

Adapter

230V AC

0-10V

12V
GND
IN1
IN2
IN3
IN4
Red
Green
Blue
White

12V

R

G

B

W

B

12/24 VDC

Adapter

12V
GND
IN1
IN2
IN3
IN4
Red
Green
Blue
White

FIBARO

RGBW

CONTROLLER

12V

R

G

B

W

12V

R

G

B

W

12V

R

G

B

W

EPILEPSY WARNING:

Stroboscope effect and rapid light changes may 

potentially trigger seizures for people with 

photosensitive epilepsy!

Reviews: