29
confIguratIon
154.
ON frame value for single click
This parameter defines value sent to devices in association groups.
The parameters consist of 4 bytes, each byte reserved for separate
channel, from least significant (IN1) to most significant (IN4).
Applicable for Basic Set and Switch Multilevel Set commands.
Parameter size
4B
Default value
4294967295 (0xFF FF FF FF – 255 for all channels)
Available
values
For every byte:
0-99, 255
155.
OFF frame value for single click
This parameter defines value sent to devices in association groups.
The parameters consist of 4 bytes, each byte reserved for separate
channel, from least significant (IN1) to most significant (IN4).
Applicable for Basic Set and Switch Multilevel Set commands.
Parameter size
4B
Default value
0 (0x00 00 00 00 – 0 for all channels)
Available
values
For every byte:
0-99, 255
156.
ON frame value for double click
This parameter defines value sent to devices in association groups.
The parameters consist of 4 bytes, each byte reserved for separate
channel, from least significant (IN1) to most significant (IN4).
Applicable for Basic Set and Switch Multilevel Set commands.
Parameter size
4B
Default value
0 (0x63 63 63 63 – 99 for all channels)
Available
values
For every byte:
0-99, 255