FIBARO FGBHCD-001 Operating Manual Download Page 7

7

OPERATING THE DEVICE

Menu

 allows to perform different actions. In order to use the menu:

1.  Press and hold the button for 3 seconds.

2.  You should hear a short signal while the LED diode blinks white.
3.  Release the button.
4.  wait for the device to indicate desired menu position with a colour:

•   White

 - confirm the start of the firmware update process

•   Green

 - send the current state of CO Alarm

•   Magenta

 - reset the CO peak value

•   Yellow

 - the device reset

5.  Press the button to confirm selection.

#5: Operating the device

Resetting the accessory to factory defaults: 

Reset procedure allows to restore the accessory back to its factory 

settings including HomeKit pairing. Stored carbon monoxide and  

temperature measurement are not deleted.
1.  Press and hold the button.
2.  Release the button when LED indicator glows white and short 

beep sounds.

3.  Click the button when LED indicator glows yellow.
4.  After few seconds the device will be reset (confirmed by red LED 

indicator and long beep).

Button

NOTE

CO Sensor must be de-

tached from the wall 

and battery level must 

be greater than 30% 

of its full capacity to 

perform the firmware 

update process.

i

Self-test 

allows to check operation of the accessory

.

To start the self-test:

1.  Press and hold the button.
2.  The LED indicator will glow white and you will hear a short beep.
3.  Release the button when you hear the first alarm sequence.
4.  Move away from the accessory to protect your hearing.

CAUTION

The alarm is very loud! 

Only the first alarm se-

quence is quieter.

!

If the self-test procedure does not result in emitting sound 

and red light signal, replace the accessory.

!

Summary of Contents for FGBHCD-001

Page 1: ...n and features 3 2 Powering the accessory 4 3 Pairing the accessory 5 4 Physical installation 6 5 Operating the device 7 6 Functionality 8 7 Visual indications acoustic signals 9 8 Battery 10 9 Specifications 11 10 Regulations 12 v1 0 EN 4 x BEEP RED LED BLINKING MOVE TO FRESH AIR ...

Page 2: ...on acidic gases silicone vapors hydrogen sulfide or sulfuric acid gas organic vapors contact with water dust and oil mist or dew condensa tion may affect the reliability of the device operation This device may not protect from long term exposure to low levels of carbon monoxide which can also lead to neurological symptoms The device is not a substitute for appropriate ventilation and exhaust syste...

Page 3: ...temperature sensor measuring ambient temperature FIBARO CO Sensor is a HomeKit enabled carbon monoxide detector using Bluetooth low energy technology Its high sensitivity allows to detect the presence of the carbon monoxide CO gas at the early stage in order to prevent carbon monoxide poisoning Alarm is signalled with a built in siren blinking LED indicator and by sending information to your iOS d...

Page 4: ... ide detector or may be used in cooperation with HomeKit technol ogy as a part of smart home system i PULL 1x CR 12 3A 3V Beep PULL 1x CR 12 3A 3V PULL 1x CR 12 3A 3V 2 Take off the cover 3 Remove the paper strip protecting the battery 4 Proper powering up will be con firmed with a short beep 5 Pair the accessory if you want to use it with HomeKit ...

Page 5: ...nsor you wish to pair 7 You can identify it CO Sensor will blink green 8 Find HomeKit Setup Code on the last page of Quick Start Guide included in the box that looks like this 9 Start pairing with your HomeKit app 10 Point your iOS device s camera at the Setup Code to scan it or en ter the Setup Code manually 11 If entered Setup Code is valid the device will complete the setup process 12 Follow in...

Page 6: ...away from the corners The accessory should not be installed in a bathroom next to heat sources within range of kids obstructed from possible carbon monoxide sources in direct sunlight The accessory should be installed by a qualified installator Do not paint the accessory The accessory should be cleaned with a slightly damp cloth or moistened tissue CEILING FLOOR NOT HERE HERE 30cm 1ft 1 5m 5ft WAL...

Page 7: ...measurement are not deleted 1 Press and hold the button 2 Release the button when LED indicator glows white and short beep sounds 3 Click the button when LED indicator glows yellow 4 After few seconds the device will be reset confirmed by red LED indicator and long beep Button NOTE CO Sensor must be de tached from the wall and battery level must be greater than 30 of its full capacity to perform t...

Page 8: ...measured temperature differs from previously reported by at least 0 5 C 0 9 F accessory reports it to your iOS device Last 2500 measurements are stored in non volatile memory of the ac cessory and can be accessed via FIBARO for HomeKit app Tamper detection The CO Sensor detects tampering when accessory is removed from its base and reports it to your iOS device Tampering is indicated with one white...

Page 9: ...battery level Replace the battery 1 x BEEP every 30s Sensor error Reset the accessory replace if no effect 2 x BEEP 1 x CYAN BLINK every 30s End of lifespan Reset the accessory replace if no effect 1 x BEEP 1 x WHITE BLINK Tamper alarm Check the housing 1 x GREEN BLINK after button press Accessory powered 1 x BEEP 1 x GREEN BLINK after powering Paired with HomeKit 1 x BEEP 1 x RED BLINK after powe...

Page 10: ...attery 3 Press and hold the button for at least one second 4 Insert a new CR123A battery observing the polarities shown inside 5 Attach the accessory to its cover by turning it clockwise and perform the test as decribed in 5 Operating the device CAUTION Using batteries other than specified may result in explosion Dispose of properly observing environ mental protection rules FIBARO CO Sensor can be...

Page 11: ...s on default settings tested with Panasonic Industrial Lithium 8 years 0 450 ppm 10ppm 5 50ppm 60 90min 100ppm 10 40min 300ppm 1 5min 85 dBA at 3 meters 10 feet 0 50 C 32 122 F 10 95 RH without condensation RED 2014 53 EU RoHS 2011 65 EU EN 50291 1 2010 Bluetooth low energy 2 4 GHz up to 50m free range 164 feet 65 x 28 mm 2 56 x 1 1 inches CAUTION Using batteries other than specified may result in...

Page 12: ...r respective holders Use of the Works with Apple HomeKit logo means that an electronic accessory has been designed to connect specifically to iPod touch iPhone or iPad respectively and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Information according REACH Th...

Reviews: