7
J7
J6
J5
J4
J3
J2
Using analogical hydrometer.
The analogical hydrometer control panel has a dial with unit of measure in a
bar, from 0 to 6 bar. The water pressure in the heating system is indicated by
the index of the black arrow.
The optimum pressure for the system is between 1 and 1.5 bar.
More than 1.5 bar you can have a maximum pressure of 2 bar (maximum
expansion of the system during the rise in temperature). More than 2 bar
pressure the system is not in the range of operation, and mechanical safety
valve (preset to 3 bar) can start to lose water.
The minimum operating pressure is 0.8 bar (+/- 0.2 bar). The differential
positive or negative tolerance is due to the operation of the water pressure
switch with fixed setting.
KEYBOARD PANEL (Control panel)
MEANING OF THE KEYS IN USER MODE
KEY
FUNCTION
J5
Change and set parameters.
J6
Change and set parameters.
J7
ON - OFF Switching
Display temperature output / Display setpoint output
Unlock error of safety thermostat
J4
Summer – Winter switching
J2
Display / Increase of heating setpoint (or room temperature)
J3
Display / Decrease of heating setpoint (or room temperature)
J
4
+ J
7
Start function degassing