15
MANUFACTURE CONSTANTS
FUNCTION Value
DELTA OFF TANK PROBE 0°C
DELTA ON TANK PROBE -1°C
INTERVENTION TEMPERATURE ANTI LEGIONELLA 65°C
INTERVENTION INTERVAL ANTI LEGIONELLA 7 Days
MAX TEMPERATURE PRIMARY 80°C
TIME OF PUMP FUNCTIONING IN ANTI-LOCK 10 sec
INTERVENTION TIME ANTI-LOCK PUMP 24H
TEMPERATURE ANTIFREEZE ON (only circulator) 7°C
TEMPERATURE ANTIFREEZE ON (heat exchanger ignition) 4°C
TEMPERATURE ANTIFREEZE OFF 20°C
SETPOINT AND PARAMETERS
FUNCTION Default RANGE
HEATING SETPOINT 60°C 30 – 75 °C
FLOOR HEATING SETPOINT 30°C 10 – 40 °C
ROOM SETPOINT (with external probe present) 20°C 10 – 30 °C
TANK SETPOINT 60°C 30 – 65 °C
TEMPERATURES
FUNCTION N°
DELIVERY TEMPERATURE t: “Ch”
TANK TEMPERATURE t: “Dh”
EXTERNAL TEMPERATURE t: “Ep”
OFFSET SETPOINT OF EXTERNAL PROBE t: “Se”
SELECTION JUMPERS enable
Jumper
0 / 1
JP7 High temperature / Low temperature plant
INSTANTANEOUS DHW SETPOINT 50°C 30 – 60 °C
JP
8
Combined / Heating only
JP
9
Sanitary with tank / Sanitary instantaneous
PARAMETERS
FUNCTION
N° def. RANGE
EXTERNAL PROBE START UP
1
0
0 – 1
BUILDING COEFFICIENT OF DISPERSION 2
35
5 – 35 °C
SANITARY POST CIRCULATION
3
15
1 – 180 sec
HEATING POST CIRCULATION
4
30
1 – 180 sec
HEATING EXCHANGER CIRCULATION STARTING
5
0
0 – 240 sec
MIN. IGNITION TEMPERATURE CIRCULATOR
6
30
0 – 50 °C
DELIVERY DIFFERENTIAL OF
SANITARY 7
1
5
0 – 20 °C
TYPE KETTLE PRESENT 8 0
0=int. with probe - 1=ext. with thermostat - 2=ext. with probe
TYPE OF SENSOR REQUIRED TANK 9 0
0=flow three-way pneumatic - 1=flow meter +three-way electric
SPEED PUMP PWM OPERATION 10 4
1=400 l/h - 2=800 l/h - 3=1000 l/h - 4=1200 l/h