Positioning unit

SERVO.D

Data: 13/01/16

file: Servo.D_ing.doc

pg 1/7

USER’S MANUAL AND MAINTENANCE

POSITIONING UNIT SERVO.D

Summary of Contents for SERVO.D

Page 1: ...Positioning unit SERVO D Data 13 01 16 file Servo D_ing doc pg 1 7 USER S MANUAL AND MAINTENANCE POSITIONING UNIT SERVO D ...

Page 2: ...or the storage of the device Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Maintenance The instr...

Page 3: ...n PROFIBUS DP The electric connection is made by the means of 3 connectors M12x1 for power supply and field bus Installation Before installing the instrument read the following warnings a Connect the instrument strictly following the instructions of the manual b Carry out the connections using the correct wires within the limits of the tension and power supply as indicated in the technical data c ...

Page 4: ... assembly To assemble the unit correctly adhere to the following instructions Set out a threaded bore M4 at distance from 103 to 105 mm from control shaft for fixing of anti rotation screw Two M4 screws can be used moreover that can be screwed in the two brass inserts M4x12 this is in case the servo motor has to make many manoeuvres or is used continuously The unit is therefore inserted through th...

Page 5: ...ase of bus connectors see instructions assembling of connectors To enter to configuration dip switch of address and of baud rate screw off the two fixing screws of cover with FIAMA logo BUS POWER SW2 SW1 ADDRESS TERM 1 2 3 4 5 6 7 8 ON ON 1 2 Set address and baud rate using dip switch SW1 SW3 as per following table 4 3 2 1 2 3 4 1 2 3 4 1 POWER SUPPLY M12x1 MALE CONNECTOR 24VDC 1 2 24VDC 3 4 GND P...

Page 6: ...ss and baud rate is necessary to switch off and turn on the Servo PROFIBUS DP Valid address from 1 to 127 The speed is measured automatically If the SERVO is the last node of net set at ON the dip switch SW2 both switches 1 and 2 at ON to plug in the ending resistance of line IMPORTANT during this phase it is advisable to pay very attention to not damage the dip switch and the electronic component...

Page 7: ...ns 1 1 3 3 1 10 1 24 1 30 1 90 1 others on request Electric wiring Connector M12x1 4 poles Protection grade IP54 IP66 on request Temperature 0 60 C Relative humidity 10 85 Directive 2014 30 EU Electromagnetic compatibility 2011 65 EU RoHS Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43016 San Pancrazio Parma Italy Tel 39 0521 672 341 ...