background image

data: 13/01/16

file: P1X_ing.doc

pag 3 di 11

function according to the following table:

KEY

FUNCTION

INDICATOR

ASSOCIATED FUNCTION

1

MAN

Manual axis movement

2

ZERO

Zero setting/presetting or zero research

3

SING

Immediate positioning at a given dimension

4

A

/

S

Automatic/semiautomatic positioning

5

PROG

Writing of dimensions and positioning programmes

6

COST

Setting of positioner machine parameters

7

TEST

Inputs/outputs tests

8

CYCL

Setting of the number of cycles to be carried out

NOTA BENE:

 in order to ease the association between the wished function and the corresponding number, on

the front panel next to every function indicator it is reported the number corresponding to the associated
function.

1. 

MANUAL AXIS MOVEMENT  (MAN)

The manual function enables to move the axis forward/backward in slow/fast mode by pressing the
numerical keys according to the following table:

KEY

AXIS MOVEMENT

7 <<

Backward fast

9 >>

Forward fast

4 <

Backward slow

6 >

Forward slow

NB: in order to move the axis the EMERGENCY input must be closed.

2. 

ZERO SETTING/PRESETTING OR ZERO RESEARCH (ZERO)

Through this function it is possible to zero set or set at a wished value (preset) the dimension of the axis
or to carry out an automatic zero research (with encoder zero notch or zero micro) to zero set or preset
the dimension.

Manual zero setting or presetting

By pressing the 

E

  key  or by enabling the 

PRESET  

input in the terminal box it is possible to zero set or to

carry out a presetting of the dimension as a function of what was set in the constant  

on page 7

Automatic zero setting or presetting (zero research)

By enabling the START input in the terminal box  (if the constant  

is set to the proper value see

page 7) the zero research is started; it occurs with the backward shifting of the axis at slow speed. When
the axis meets the zero notch the dimension is set to zero and the movement is interrupted.
In order to use this function it is necessary that the zero microswitch (or the proximity switch) is connected
to the  

PRESET 

input of the positioner.

3. 

IMMEDIATE POSITIONING AT A SINGLE DIMENSION  (SING)

This mode was created to immediately position the axis at a given dimension without intervening on the
positioning programmes.  Press the 

C

  key, enter the dimension through the numerical keypad, confirm by

pressing  

E

  and close the  

START

 input to start the movement of the axis or hold down the  

START

- key for

about 2 seconds.  If the 

EMERGENCY  

input is closed, the positioner controls the motion to reach the set

dimension.  Once the axis reached the set position, it is possible to enable the 

END OF POSITIONING 

and

AUX

 outputs according to what is set in the 

0/

  constant  (see page 6)

Summary of Contents for P1X

Page 1: ...mes giving the possibility to manage for every dimension the number of parts that are to be processed in sequence as well as the number of cycle repetitions In order to optimize positioning accuracy there are some parameters that can counterbalance system inertia clearances and wear and tear of mechanical couplings Find below the other features characterising the instrument automatic semiautomatic...

Page 2: ...e work number etc For the relevant connections see wiring diagram on page 10 Description of the front panel The display1 always displays the axis dimension whereas the other displays show different parameters as a function of the positioner status The function indicators show the currently selected function PROGRAMMING The keys used for programming are the following P Function choice programming E...

Page 3: ...th encoder zero notch or zero micro to zero set or preset the dimension Manual zero setting or presetting By pressing the E key or by enabling the PRESET input in the terminal box it is possible to zero set or to carry out a presetting of the dimension as a function of what was set in the constant on page 7 Automatic zero setting or presetting zero research By enabling the START input in the termi...

Page 4: ...er of memorised dimensions which must not exceed 99 for instance it is possible to create as ultimate limits either 99 programmes made by a single dimension or one single programme made by 99 dimensions The modification of the dimensions is protected by a password the password is requested through the display of letter P on display3 and of three zeroes the first one of them is blinking on display2...

Page 5: ...nt is used for the applications that need cutting with material removal 2 PreStop The positioner stops the axis movement when it reaches the dimension amounting to the difference between the set dimension and the PreStop value This parameter enables to counterbalance the positioning inertia in systems with constant inertia It is advisable to enter the PreStop parameter after setting all the other ...

Page 6: ...ing between 0 and 9999 milliseconds for all the motion reversing manoeuvres 11 Deviation dimension By setting this constant to a value differing from zero at the end of the positioning the instrument waits for the switchover from open to closed of the WORK COUNTER input to carry out an onward shifting of a dimension equal to the Deviation Dimension after that when a time equal to the Deviation Ret...

Page 7: ...he zero research automatic cycle see on page 3 the zero setting presetting or zero research function Zero automatic research mode1 In the automatic zero setting function when the START key is pressed the slow backward motion of the axis is started searching for the zero input When the zero point is reached the axis motion continues for 2 seconds more and then stops and carries out the dimension pr...

Page 8: ...n inch From tenth of mm to hundredths of an inch From mm to hundredths of an inch From mm to tenths of an inch From cm to hundredths of an inch From dm to inches Sexagesimal degrees with display in degrees and prime numbers Sexagesimal degrees with display in degrees 7 INPUTS OUTPUTS TEST TEST In order to have access to the test function it is necessary to enter the password 273 In the inputs test...

Page 9: ... P 8 SETTING OF THE NUMBER OF CYCLES TO BE CARRIED OUT CYCL By number of cycles we mean the number of repetitions of the positioning programme The automatic functioning mode involves the possibility to repeat the selected programme By setting a number of cycles greater than 1 once the last dimension of the positioning programme has been carried out at the next command by the work counter input the...

Page 10: ...cer wiring diagram AUX OUTPUT relay START FORWARD BACKWARD relais GND A A B B 12V 24 Vac 24VDC 230 Vac 115 Vac P1X2 P1X3 P1X1 P1X0 0 0 0 0 START input SLOW FAST relay NC SLOW Transducer wiring diagram 18 20 17 19 21 22 GND A B 12V A B GND A B Vcc Connection bidirectional encoder open collector NPN or push pull output NPN A B 12V A B GND GND A B Vcc PNP 19 22 20 18 17 21 Connection bidirectional en...

Page 11: ...Line driver differential 12V Maximum counting frequency 100 KHz Operating procedure mode Semiautomatic Automatic Absolute line Manual Single positioning Test Possibility to create working programmes 99 steps of program memory with the possibility of specifying the number of pieces and the number of cycle repeats Data storage with the machine switched off by EEPROM memory Extractable terminal junct...