Hollow shaft display with serial output
EP43RS / EP46RS
Date: 06/04/21
File: EP4RS_4.1_ing.doc
Rev: 4.1
Page: 7/12
Serial connection protocol
The device has a serial output connection RS485 with MODBUS RTU protocol to dialogue with remote units.
When a power is supply is not available, the serial port is not active and the instrument does not respond to
the master. Below is a list of the registers of the instrument with the relative addresses and number of bytes.
It is possible to read and write these registers, using a reading/writing ModBus compatible query.
ADDRESS
REGISTER NAME
SIZE (bytes)
RANGE
0
0
0
0
0
value to be displayed after one
complete rotation of the shaft
4
-99999...99999
2
decimal point position for
0
0
0
0
2
0...4
3
+%
+%
+%
+%
position of decimal point
2
0...4
4
+//
+//
+//
+//
button activation mode
2
000... 0x151
5
%.
%.
%.
%.
count direction
2
0...1
6
.
.
.
.
Preset0 value
4
-99999...99999
8
,,
,,
,,
,,
backlash compensation value
4
-99999...99999
10
+,
+,
+,
+,
target value tolerance
2
0...59999
11
0#//
0#//
0#//
0#//
battery status
2
0x0000 = battery OK
0xFFFF = battery needs
substitution
0x00FF = battery
completely depleted or
malfunctioning(refer to
battery status section)
12
-0,/
-0,/
-0,/
-0,/
Current value
4
-99999...99999
14
//
//
//
//
Target value
4
-99999...99999
16
SAVE
setting the value 0x5A4E, the
parameters transferred by
modbus are saved in the
EP43RS / EPRS permanent
memory
2
0x5A4E