background image

 

Manual 

FernTel IP Z2 UL

 

7

 

 

3.2

 

Care and Maintenance 

The telephone is maintenance-free. Still, if the operating area is highly contaminated 
by dust, fat, oil etc., the device should be cleaned from time to time. 

The  device  may  only  be  cleaned  using  a  damp  cloth  in  order  to  avoid  electrostatic 
charging. 

Never use sharp objects for cleaning. 

During  maintenance,  check  accessible  seals  for  function,  e.g.  regarding  possible 
damage  or  positioning.  If  the  seals  are  damaged,  operating  the  telephone  is  not 
allowed. Damaged seals must be replaced. 

3.3

 

Disposal 

The complete device should be disposed of as electronic waste. When the device is 
disassembled,  plastics,  metals  and  electronics  components  are  to  be  disposed  of 
separately. In every single case the national requirements and regulations for waste 
disposal must be observed. 

3.4

 

Warning and Security Instructions 

This device is an explosion and weatherproof telephone especially for use in a harsh 
industrial environment.  

The following warning and security instructions must be respected: 

 

The telephone is build up in protection for use in Class 1, Division 2, Groups A, 
B,  C  and  D  or  non-hazardous  locations  only.  It  must  be  connected  and  used 
with  the  required  voltages  only.  The  connection  must  be  done  in  perfect 
order. The connection cable has to be mounted without risk of stumbling. 

 

It must be paid attention that the telephone, the connection cable, etc. must 

not be damaged. In a damaged state the use of the telephone is not allowed. 

 

For  using  the  telephone  the  laws  and  the  industrial  regulations,  the  accident 

prevention, respectively the electrical regulations must be respected. 

 

For  repairing  only  original  exchange  parts  are  allowed,  which  have  to  be 

changed  professional.  Other  exchange  parts  may  cause  damages  and  the 
warranty will be lost.  

Page

Summary of Contents for FernTel IP Z2 UL

Page 1: ...Explosion proof UL certified VoIP telephone Manual FHF BA 9620 51 09 12 FernTel IP Z2 UL Tabletop unit...

Page 2: ...fore supplied under exclusion of any liability or warranty of suitability for specific purposes FHF reserves the right to improve or modify this documentation without prior notice Note Please read the...

Page 3: ...4 2 1 1 LAN Connection 5 2 1 2 Connection Potential Equalisation 6 2 2 Setup 6 2 3 Operating Position 6 3 Information 6 3 1 Service 6 3 2 Care and Maintenance 7 3 3 Disposal 7 3 4 Warning and Securit...

Page 4: ...he following Working environment temperature range o 20 C Ta 55 C 4 F Ta 131 F Storage and transport temperature o 25 C Ta 70 C 13 F Ta 158 F 2 Commissioning For operation and commissioning the applic...

Page 5: ...ng the cable please make sure the exposed conductors are placed in the plug connector and are securely fastened 2 1 1 LAN Connection Remove the keypad plate Position 6 of the FernTel IP Z2 UL guide th...

Page 6: ...on are the terminals Position 17 external and Position 18 internal available The stainless steel plate of the keypad is also connected with the potential equalisation inside the telephone This connect...

Page 7: ...sal must be observed 3 4 Warning and Security Instructions This device is an explosion and weatherproof telephone especially for use in a harsh industrial environment The following warning and securit...

Page 8: ...unting After repairing of the device for use in dust environment the repaired parts have to be tested again The speech speed hopper of the handset consists out of a not electrical conductive plastic m...

Page 9: ...age of the device and thus present a potential danger for the user Such unfavourable ambient conditions are o Humidity of air too high 75 rel condensing o Moisture and dust pay attention to the degree...

Page 10: ...en o When the work is done plug the keypad back on and place the keypad insert back on the lower part of the device Make sure the seal is correctly positioned and in perfect working order Then tighten...

Page 11: ...Manual FernTel IP Z2 UL 11 4 Declarations and Approvals 4 1 UL Certificates FernTel IP Z2 UL Page...

Page 12: ...12 Manual FernTel IP Z2 UL Page...

Page 13: ...e connecting cable 6 13 mm Connection potential equalisation 1 5 4 mm2 Ringing volume Max ca 95 dB A in 1 m distance Housing Height x Width x Depth 293 x 191 x 128 mm Weight telephone incl telephone m...

Page 14: ...ations UL50 UL50E UL60950 1 UL60950 22 ANSI ISA 12 12 01 2011 FCC Part 15 Control numbers 3MSC 4HG9 File numbers E304856 E337081 Enclosure type rating Type 3 Hazardous location designation Class I Div...

Page 15: ......

Page 16: ...Subject to alterations or errors FHF Funke Huster Fernsig GmbH Gewerbeallee 15 19 D 45478 M lheim an der Ruhr Phone 49 208 82 68 0 Fax 49 208 82 68 286 http www fhf de e mail info fhf de...

Reviews: