Ampilifier Specifications

Load:

8 ohms

 

     650 

  900 

  1000 

  1250 

  1500 

W

4 ohms

 

     1000 

  1500 

  1800 

  2400 

  3000 

2 ohms

 

      

 N/A

 

   

 

 N/A

 

  3000 

  4000 

  5000 

    

Maximum output voltage at rated load - V peak

 

  105 

  135 

  130 

  150 

  175 

V

Gain

 

           32dB

THD+N

 

          Typical 

0.05% 

Ohm 

kHz 

THD+N 

Input impedance 

 

         20 

Ohms 

electronically 

balanced

Frequency response 

 

         20 

Hz 

– 

20 

kHz

Cooling  system

 

         single 

high 

CFM 

fan 

rear 

to 

front 

airflow

Load protection 

 

         DC 

on 

output 

and 

clip 

limiter

Amplifier protection 

 

         Short 

circuit 

on 

output 

connector, 

over 

current, 

thermal

Indicators  

   

 

       green LED = signal present      yellow LED = -3dB drive      clip red LED = clip      protect red LED = over current, thermal, occasional flash equals clip limiter activated, 4 second mute on amplifier power up.

Power connector 

 

         NACFCA 

20A 

230 

VAC 

Neutrik 

PowerCon 

connector.

Power operational range 

        230VAC 

+-10% 

50/60 

Hz.

Dimensions

 

          H88mm 

W483mm 

D510mm. 

Standard 

RU 

rack 

mount

Weight

 

 

      

10 

kg 

   

10 

kg 

   

12 

kg 

   

12 

kg 

   

12 

kg

-20

-20

On

C

D

A

B

-6

-2

-12

-6

-20

-2

Protect

-12

Ch

-2

-12

-6

-20

-2

-3dB

-12

Sig

-6

Clip

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

4 x 1 0 0 0   W A T T

FFA - 4004

-20

-20

On

C

D

A

B

-6

-2

-12

-6

-20

-2

Protect

-12

Ch

-2

-12

-6

-20

-2

-3dB

-12

Sig

-6

Clip

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

4 x 1 5 0 0   W A T T

FFA - 6004

-20

On

A

B

-6

-2

-12

-6

-20

-2

-12

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

2 x 3 0 0 0   W A T T

FFA - 6000

-20

A

B

-6

-2

-12

-6

-20

-2

-12

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

2 x 5 0 0 0   W A T T

FFA -10000

On

B

A

-20

A

B

-6

-2

-12

-6

-20

-2

-12

Sig

Clip

-3dB

Protect

Ch

Sig

Clip

-3dB

Protect

Ch

FFA - 8000

On

B

A

2 x 8 0 0 0   W A T T

Power ratings 

 

 

 

 

 

 

 

     Measured per channel, driven at 1 kHz sine wave, 240 VAC mains supply voltage to no more than 1% THD

pg 13

Summary of Contents for FFA-10000

Page 1: ...FFA Series Amplifiers OEM variants Operation Manual Issue 1 1 Sept 2012...

Page 2: ......

Page 3: ...allation pg 6 Mains power connection pg 7 8 Audio signal input connection pg 9 Audio power output load connection pg 10 11 Amplifier load protection pg 12 Amplifier range technical specifications pg 1...

Page 4: ...FIED PERSON ONLY THE FFA 4004 FFA 6004 FFA 6000 FFA 8000 FFA 10000 MUST BE EARTHED IT SHOULD NOT BE NECESSARY TO REMOVE ANY PROTECTIVE EARTH OR SIGNAL CABLE SHEILD CONNECTIONS TO PREVENT GROUND LOOPS...

Page 5: ...to its specified minimum rated load FFA amplifier series features Amplifier overview FFA specialise in designing power efficient Class D amplifiers and high capacity switching power supplies Innovativ...

Page 6: ...has one high CFM fan which is designed to pull cool air from the rear of the unit and blow hot air out of the front of the unit The fan must only be used in this direction due to the high pressure co...

Page 7: ...er is mounted in must also be connected to the same grounding circuit The amplifier must not be used if the earth connection is not properly terminated this is very important for personal safety and s...

Page 8: ...ses must not be replaced as further damage could occur Please return the amplifier for service POWERING UP The FFA 4004 and FFA 6004 have a single power on switch located on the right side of the fron...

Page 9: ...phase positive XLR pin 3 signal COLD or out of phase negative Unbalanced connections can be used if pins 1 and 3 are connected together via a wire link Pin 2 is signal HOT in phase IMPORTANT At all ti...

Page 10: ...speaker cable to be connected directly into the output This is useful when connecting the amplifier outputs to a biamplified loudspeaker system without using an ancillary patching panel An example of...

Page 11: ...are connected internally to the amplifier outputs and are connect as follows 1 positive 1 negative 2 positive 2 negative We have specified a pair of parallel outputs so that it is possible to use 2 x...

Page 12: ...if the thermal threshold is exceeded Amplifier channels will un mute when sufficient cooling has taken place If the FFA amplifiers are to be fitted within a sealed type rack enclosure with input fans...

Page 13: ...er connector NACFCA 20A 230 VAC Neutrik PowerCon connector Power operational range 230VAC 10 50 60 Hz Dimensions H88mm x W483mm x D510mm Standard 2 RU rack mount Weight 10 kg 10 kg 12 kg 12 kg 12 kg 2...

Page 14: ...iew Medium to larger full range and dedicated bass loudspeakers bi amplified stage monitor systems components within large format touring or installation loudspeakers low mid high mid and HF 4 ohm dri...

Page 15: ...A 6000 FFA 8000 and FFA 10000 models when sold to an end user by FFA or FFA authorised distributor dealer are warranted by the seller against defects in workmanship and materials for a period of 5 fiv...

Page 16: ...nd accordingly reserve the right to change features and specifications without prior notice Dealer name Dealer address Dealer tel no Dealer contact name Invoice receipt no Postcode Date of purchase FF...

Page 17: ......

Page 18: ...www fullfataudio com Full Fat Audio Ltd Unit 4 The Granary Fairclough Hall Farm Weston Hitchin Hertfordshire SG4 7DP UK Tel 44 0 1462 790700 email info fullfataudio com...

Reviews: