HWB Series Programming Instructions 

 

The display shows the current tank temperature 
in 

°

 Celsius when in normal operating mode. 

 

Programming: 

 
Temperature may be set in either Celsius or Fahrenheit.  
 

1.  Remove the top cover of the unit. 

The control board is located on the left side near the front. 
 

2.  Turn the power switch 

ON

 

3.  Press and hold 

SET

 for 3 seconds. 

Temperature setting in 

°

C will be displayed and 

°

C indicator lamp will be lit. 

To adjust, press and release 

SET

 quickly to advance one degree at a time. 

Range: 82-98 

°

 

4.  Press and hold 

SET

 for 3 seconds. 

Temperature setting in 

°

F will be displayed and 

°

F indicator lamp will be lit. 

To adjust, press and release 

SET

 quickly to advance one degree at a time. 

Range 180-208 

°

Only the last 2 digits of the temperature will be displayed. 
Example: 185

°

F is displayed as 

8 5

      205

°

F is displayed as 

0 5

 

 

5.  Press and hold SET for 3 seconds. The fill valve % will be displayed and the %FV 

indicator lamp will be lit. 
To adjust, press and release 

SET

 quickly to advance one percent at a time. 

Refer to the chart below for the proper setting for your model and voltage. 
Range: 15% – 100%. 
 

6.  The unit will return to normal operating mode after 30 seconds without programming 

activity. 

 

    Select the model and actual voltage to determine the correct %FV setting for step 5. 

 Heater 

Actual 

 

 

%FV 

Model Configuration 

Voltage 

Phase 

Setting 

HWB-5 (-1) 

1 X 3000 watt 

120/208 

1 ph. 

15 

 

  

120/220 

1 ph. 

15 

  

120/240 

ph. 

17 

HWB-10 (-1) 

2 X 3000 watt 

120/208 

1 ph. 

25 

 

  

120/220 

1 ph. 

28 

  

120/240 

ph. 

33 

HWB-15 (-1) 

2 X 3000 watt 

120/208 

1 ph. 

25 

 

  

120/220 

1 ph. 

28 

  

120/240 

ph. 

33 

HWB-15 (-2) 

3 X 3000 watt 

120/208 

3 ph. 

37 

 

  

120/220 

3 ph. 

42 

  

120/240 

ph. 

50 

HWB-25 (-1) 

6 X 3000 watt 

120/208 

3 ph. 

74 

  

120/220 

ph. 

83 

  

120/240 

ph. 

99 

HWB-25 (-2) 

6 X 4000 watt 

120/208 

3 ph. 

99 

 

 

120/220 3 

ph. 

100 

  

120/240 

ph. 

100 

 

 

TEMPERATURE CONVERSION 

°

°

82 180 
83 181 
83 182 
84 183 
84 184 
85 185 
85 186 
86 187 
87 188 
87 189 
88 190 
88 191 
89 192 
89 193 
90 194 
90 195 
91 196 
92 197 
92 198 
93 199 
93 200 
94 201 
94 202 
95 203 
95 204 

96* 205* 

97 206 
97 207 
98 208 

 

*factory setting 

 

 

 
 