9
Relay Test
Tests the individual relays which control various components.
Use the UP or Down button to actuate the relays.
90 Fill
Valve
91 Dilution
Valve
92 Brew
Valve
93 Ready
Light
94 Brew
Light
95
Heater Triac
To protect the heaters, this test will work only if the tank is full.
Error Codes
001 Software - System Reloaded Defaults
003 Internal CPU or Board Error
050* Shorted Temperature Probe
051* Open Temperature Probe
060 Flow Error
075 Brew Basket Sensor Open
076 Container Sensor Open
100 Initial Fill Error (> 10 minutes)
101 Error On Refill (> 2 minutes)
102 Unwanted Fill
200 Flat Line Temperature / Shorted Heater
201 Open Heater
255 Stuck Switch
To reset error codes, turn the power switch off and on.
Error 050 and 051 must be reset through the Master Clear function – see address #57 in Diagnostics.
Warning: During these
tests, hot water may
be dispensed from
the valve being tested.
Summary of Contents for Extractor TBS-21A
Page 3: ...3 Dimensions Utility Connections DWG 201073 005 ...
Page 10: ...10 Wiring Diagram ...
Page 14: ...14 Brewer Parts Figure 1 ...