![Fetco CBS-2151XTS Users Manual And Operator Instructions Download Page 20](http://html1.mh-extra.com/html/fetco/cbs-2151xts/cbs-2151xts_users-manual-and-operator-instructions_2285230020.webp)
20
CBS_2152XTS—Twin 1½ gallon version Electrical Configurations
USA and Canada
CBS_2152XTS—Twin 1½ gallon version Electrical Configurations
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E215251
E215251M
2 X 3.0 kW
208-240
1
2+G
Hardwired
4.6-6.1
22.4-25.8
15.3 gal/58 liters
Selectable—sold as 1 phase
3 X 3.0 kW
208-240
3
3+G
Hardwired
6.9-9.1
19.5-22.5
22.5 gal/85 liters
E215252
E215252M
2 X 5.0 kW
208-240
1
2+G
Hardwired
7.6-10.1
36.9-42.5
25.3 gal/97 liters
Selectable—sold as1 phase
3 X 5.0 kW
208-240
3
3+G
Hardwired
11.4-15.1
32.0-36.9
38.3 gal/145 liters
E215253
E215253M
2 X 4.0 kW
208-240
1
2+G
Hardwired
6.1 - 8.1
29.3 - 33.8
19.8 gal/75 liters
Selectable—sold as1 phase
3 X 4.0 kW
208-240
3
3+G
Hardwired
9.1-12.1
25.8 - 28.9
29.5 gal/112liters
North America & International Versions
CBS_2152XTS—Twin 1½ gallon version Electrical Configurations
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E215292 E215292M
2 X 3.0 kW
208-240
1
2+G
Hardwired
4.6-6.1
22.4-25.8
15.3 gal/58 liters
E215293 E215293M
3 X 3.0 kW
208-240
3
4+G
Hardwired
6.9-9.1
19.5-22.5
22.5 gal/85 liters
E215294 E215294M
2 X 5.0 kW
208-240
1
2+G
Hardwired
7.6-10.1
36.9-42.5
25.3 gal/97 liters
E215295 E215295M
3 X 5.0 kW
208-240
3
4+G
Hardwired
11.4-15.1
32.0-36.9 38.3 gal/145 liters
Has UL & cUL and NSF-4 certification. Not certified CE
International-Not
CE
CBS_2152XTS—Twin
1½ gallon version Electrical Configurations
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E215290 E215290M
3 X 3.0 kW
220/380 or 240/415
3
4+G
Hardwired
9.1 11.8-12.9
22.5 gal/85 liters
E215291 E215291M
3 X 5.0 kW
220/380 or 240/415
3
4+G
Hardwired
15.1 19.5-21.4 38.3 gal/145 liters
Has UL & cUL and NSF-4 certification. Not certified CE
EXPORT/Japan
CBS_2152XTS—Twin 1½ gallon version Electrical Configurations
EXPORT Electrical Configurations CBS_2151XTS—Single 1½ gallon version
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
E215280
E215280M
3 X 3.0 kW
200
3
3+G
Hardwired
6.5
18.6
17 gal/64 liters
CE EXPORT
CBS_2152XTS—Twin 1½ gallon version Electrical Configurations
Configuration Codes
Plastic
Brewbasket
Stainless Steel
Brewbasket
Heater
Configuration
Voltage Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Brew-Volume/Hour
(1½ gallon per batch)
(CE) E215261 (CE) E215261M
3 X 3.0 kW
230/400
3
3L,N,PE
Hardwired
8.6
12.4
22.5 gal/85 liters
(CE) E215262
(CE) E215262
3 X 5.0 kW
230/400
3
3L,N,PE
Hardwired
14.1
20.4
38.3 gal/145 liters
Has CE and NSF-4 certification. Internal EMI filter. Not cUL and UL listed