Batch Settings 

 

Press 

STOP

 to continue. 

 

Batches are numbered 
               

1

 (top switch) 

            and 

2

 (bottom switch) 

 

Next, the first batch parameter is displayed – batch 1, brew volume  
Use the

 UP

 and

 DOWN

 buttons to adjust.                 Display: 

1.1        64

 

• 

Press the 

STOP

 button to go to the next parameter – brew time. 

 Display: 

1.2   04.00

 

 

Repeat the last step until all parameters are programmed for batch #1. 
(See the chart below for an explanation of each parameter.) 

 

Next, batch #2 programming begins.                         Display: 

2.0     OFF

 

Batch 2 may be disabled by leaving it set to 

“OFF”.

 

Change to 

“ON”

 to enable. Batch 1 cannot be disabled. 

 

After both batches are programmed, the temperature settings are next. 

Display: 

7         200

 

Summary of Contents for CBS-2021 e Series

Page 1: ...800 338 2699 847 719 3000 techsupport fetco com www fetco com 2009 Food Equipment Technologies Company Part P109 REV 000 CBS 2021e Series Programming Guide...

Page 2: ...Controls...

Page 3: ...STOP button when the software version is displayed Example VER 32 A The STOP button is used to advance from one setting to the next It is illuminated green when in Programming mode The BREW buttons a...

Page 4: ...OP button to go to the next parameter brew time Display 1 2 04 00 Repeat the last step until all parameters are programmed for batch 1 See the chart below for an explanation of each parameter Next bat...

Page 5: ...change from ounces to liters see Advanced Setting 59 X 2 Brew Time Min Sec 01 30 05 00 04 00 X 3 Bypass Percent Off 30 Off Percentage of total brew volume X 4 Prewet Percent Off 25 Off Percentage of t...

Page 6: ...elsius see 58 in Advanced Settings 8 Hot Water Service Auto Off On ON Auto Faucet will dispense only when not brewing On Faucet always enabled Off Faucet always disabled 9 Brew Temperature Protection...

Page 7: ...Settings Diagnostics Loop back to start of batch programming ON Enter Advanced Settings Diagnostics Press STOP to continue Important After programming you must press and hold the HOT WATER button to...

Page 8: ...rical resistance of the water in kilohms as measured between the water level probe and the tank If greater than 200 or if the tank is not full the display will read 51 Water Level Sensitivity LO HI LO...

Page 9: ...ings to default factory settings 0 Do not reload defaults 1 Reload all defaults If 1 is selected you must advance to the next address for this change to take effect 58 Temperature Scale F or C F F Fah...

Page 10: ...If 59 is oz 0 50 1 50 If 59 is LTR 44 1 30 Use this to compensate for minor discrepancies in actual volume versus programmed volume Set lower to increase volume higher to decrease volume FETCO EXTRACT...

Reviews: