12
The specifi ed illustrations can be found at the
beginning of the operating instructions.
Pictograms
Note,
Danger!
Manual, read the instructions
Warning
: The appliance contains dust
hazardous to health.
1 Intended
use
The vacuum cleaners are designed as specifi ed
for the aspiration and evacuation of noxious dusts
industrial threshold limit values (LTL-values) up
to 0.1 mg/m³ and of wood dusts corresponding
to dust class ‘M’ in accordance with IEC 60335-
2-69.
The vacuum cleaner is designed as specifi ed for
extracting water.
The vacuum cleaner is designed in accordance
with EN 60335-1 and EN 60335-2-69 for a higher
loading in industrial use.
2 Safety
instructions
- Only use original Festool accessories.
- Warning
: The appliance contains dust hazardous
to health. Emptying and maintenance opera-
tions, including removal of the dust collection
means, must only be carried out by authorised
personnel wearing suitable personal protection.
Do not operate without the full fi ltration system
fi tted.
- The machine is not intended for use by per-
sons (including children) with limited physical,
sensory or mental ability or without suffi cient
experience and/or knowledge, unless they are
supervised by a person responsible for their
safety or have been instructed on how to use
the machine. Children should always be super-
vised to ensure that they do not play with the
machine.
- If used to extract dusts with LTL values or large
quantities of beech or oak sawdust, only one
dust source (electric or air tool) may be con-
nected.
- The appliance may be operated only in an ad-
equately ventilated space (in compliance with
national industrial safety provisions).
- Do not suck in any sparks or hot chippings.
- With the exception of wood dust, do not suck in
any fl ammable or explosive dusts such as mag-
Mobile dust extractors
Technical data
Power consumption
350 - 1200 W
Connected load to appliance plug socket max.:
EC
2400 W
CH, DK
1100 W
GB 240 V/110 V
1800 W/500 W
AUS
1200 W
Volume fl ow (air) max., turbine
228 m³/h
Vacuum max., turbine
23000 Pa
Filter surface
14000 cm2
Suction hose
Ø 27 mm x 3.5 m
Sound pressure level in compliance
with EN 60704-2-1
72 dB(A)
Power cable length
7.5 m
Protection type
IP X4
Container capacity
CTM 44 E/CTM 44 LE
44 l
CTM 55 E
55 l
Dimensions L x W x H
CTM 44 E/CTM 44 LE/ CTM 55 E
710 x 380 x 935 mm
Weight
CTM 44 E/CTM 44 LE
20 kg
CTM 55 E
22 kg
Summary of Contents for CTM 44 E
Page 2: ......
Page 3: ...1 1 9 1 7 1 8 1 10 1 3 1 1 1 4 1 2 1 11 1 12 1 6 1 5 1 13 1 14 M M ...
Page 4: ...2 2 1 2 2 2 3 2 11 2 12 2 6 2 4 2 5 2 9 2 8 2 7 2 10 ...
Page 5: ...3 4 2 4 1 3 3 3 4 3 2 3 1 4 ...
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......