![Festool CDD 9.6 FX Instruction Manual Download Page 5](http://html.mh-extra.com/html/festool/cdd-9-6-fx/cdd-9-6-fx_instruction-manual_2284596005.webp)
5
Technical data
Cordless drill/screwdriver
CDD 9.6 FX
CDD 12 FX
Motor voltage
9.6 V
12 V
Idle-running speed 1. speed
0 380 rpm
0 - 380 rpm
2. speed
0 - 1100 rpm
0 - 1100 rpm
Max torque
Soft boring (wood)
10 Nm
18 Nm
Hard boring (metal)
26 Nm
30 Nm
Adjustable torque
0.5 - 5 Nm
1 - 7 Nm
Chuck capacity
1 - 10 mm
1,5 - 13 mm
Max. drill diameter for metal / wood
12 mm / 20 mm
14 mm / 25 mm
Tool fitting in chuck
1/4
1/4
Weight with battery pack
1.8 kg (4.0 lbs)
2.0 kg (4.4 lbs)
Charger
MC 15
Supply voltage (input)
120 V ~
Line frequency
60 Hz
Charging voltage (output)
4.8 - 12 V (DC)
Charging current quick charge
max. 7.5 A
Compensation charge pulsating app.
0.03 A
Charging time for NiCd 1.4 Ah
app. 13 min
NiCd 1.7 Ah
app. 15 min
NiCd 2.0 Ah
app. 18 min
Weight
0.9 kg (2.0 lbs)
Battery pack
BPH 9.6 C
BPH 12 C
Order number
488 437
488 438
Voltage
9.6 V
12 V
Cells
8 x 1.2 V, NiCd
10 x 1.2 V, NiCd
Capacity
2.0 Ah
2.0 Ah
Temp. range for charging
5 - 45 °C
5 - 45 °C
Monitoring of charge
by means of NTC thermistor
Weight
0.5 kg (1.1 lbs)
0.6 kg (1.3 lbs)
The illustrations mentioned can be found at the beginning of the operating instructions.
1 Symbols
V
volts
A
amperes
Hz
hertz
W
watt
alternating current
n
0
no load speed
Class II Construction
rpm
revolutions per minute
2
Intended use
The cordless drill/screwdrivers are suitable for
drilling metal, wood, plastic and similar materials,
as well as for fastening and screwing down of
screws with a diameter up to 6 mm.
The chargers have been designed to charge the
battery packs specified under 3.2.
The user will be liable for damage due to improper
use.
3
Preparation for initial operation
3.1
Remove battery pack from unit
The battery pack (1.2) is unlocked and can be
removed by pressing the switch (1.1) downwards.
3.2
Charge battery pack
a) MC 15
The charger MC 15 can be used to charge all
NiCd-FESTOOL battery packs between 4.8 V and
12 V in the battery chamber (3.1).
The charge process is controlled by a micro-
processor. The optimum charging current is
always used depending on the temperature,
voltage and internal resistance.
The LED (3.2) indicates the respective charging
operation of the charger.
LED yellow - steady =
Charger is ready for use.
LED green - flashing =
Battery pack being charged.
LED green - fast flashing =
Battery pack being charged at max. charging
current.
LED green - steady =
Battery pack fully charged, conservation
charge on.
LED red - flashing =
General malfunction, e. g. incorrect polarity
of battery pack, full contact not being made,
short-circuit, battery pack faulty.
LED red - steady =
Temperature of battery pack is outside
permissible limit.
If the battery pack is removed from the charging
chamber during charging, charging can only be
continued after 1-2 seconds when the LED shows
a steady yellow.