![Festool 575525 Instructions Manual Download Page 11](http://html.mh-extra.com/html/festool/575525/575525_instructions-manual_2285090011.webp)
11
CTL SYS
Insert the mains power cable in the cold-device
connector
[2]
and in an earthed socket.
Lay the mains cable through the recess
[2]
.
The switch
[1-8]
serves as an on/off switch.
Using the
[1-9]
switch, switch between the AUTO
and MAN settings.
”MAN” switch position
Appliance socket
[1-10]
is connected to the power,
the dust extractor starts.
”AUTO” switch position
Appliance socket
[1-10]
is connected to the power,
the dust extractor starts when the connected tool
is switched on.
Pull the plug from the socket when the
machine is not in use and prior to main-
tenance and cleaning work.
6.2
Connecting electric power tools
WARNING
Risk of injury
Observe the maximum appliance socket con-
nected load (see chapter “Technical data”).
Switch off the electric power tool
Connect the electric power tool to the appliance
socket
[1-10]
.
6.3
Connecting the suction hose
at the extraction opening [3a]
Connect the suction hose to the elbow at the
extraction opening.
at the exhaust opening [3b]
Open fl ap at rear of dust extractor.
Connect suction hose to elbow at exhaust
opening.
7 Settings
7.1 Temperature
monitoring
Before reaching a critical temperature, the
temperature monitor switches off the dust
extractor.
Switch off the dust extractor, allow to cool for
about 5 minutes, then switch on again.
Not possible to switch on: Contact Festool
customer service workshop.
7.2
Connect with the T-Loc
The dust extractor can be closed, opened and
connected by turning the T-Loc:
– Close dust extractor
[4a]
.
– Open dust extractor
[4b]
.
– Connect dust extractor to storage box
[4c]
.
Before lifting, always close the T-Loc
at the dust extractor or connect to the
storage box and check for secure holding.
Max. load for connection to other Systainers: 20 kg
7.3
Use/Adjust carrying strap
Max. permissible load of carrying strap: 20 kg
The carrying strap can be attached in two different
positions:
– Carrying the dust extractor: Carrying strap at
dust extractor
[5a]
– Carrying storage box with dust extractor:
Carrying strap at storage box
[5b]
Before lifting, check the carrying strap for
proper functionality and put T-loc at dust
extractor into corresponding position.
Adjust the length of the carrying strap at the
adjusting tab
[5c]
.
8 Working
CAUTION
Hazardous dust
Damage to the respiratory passage
Always use a fi lter or disposal bag!
Two cleaning nozzles are stored in the
inside of the dust extractor
[6-1]
.
Observe the following instructions:
– The dust extractor is a stationary system and
not suitable for pulling at the cable and hose.
Use handle
[1-4]
.
– Static charge may occur if an antistatic suction
hose is not used. The user may suffer an electric
shock.
When extracting dust that exceeds the
permitted limit values, only extract from
a single machine (electric or air tool).
Observe
the following when extracting dust
generated by operating electric power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values
: Exhaust air max. 50% of the clear
air volume
Formula
: Room volume V
R
x air renewal rate L
W