completely charged with plugged in charg
ing cable [1-11].
LEDs light up in
starting sequence
SYS‑PST 1500 Li HP powers up or starts.
LED 1 flashes green
Ready for operation
SYS‑PST 1500 Li HP almost completely dis
charged.
Charging (see section
).
1 > LED < 8 light up
green
Ready for operation
Number of continuously lit green LEDs cor
responds to state of charge.
All LEDs continuous
ly light up green
Ready for operation
SYS‑PST 1500 Li HP is charged.
1 > LED < 8 light up
green
Remaining LEDs
light up green in se
quence from left to
right
Not ready for operation, charging mode
SYS‑PST 1500 Li HP charging.
Number of lit green LEDs corresponds to
state of charge.
7.5
Troubleshooting
1 > LED < 8 light up
yellow
Overcurrent
AC output [1-3] has been deactivated.
Switch off (see section
).
Wait for 10 seconds.
Switch on (see section
1 > LED < 8 flash yel
low
Overheating
AC output [1-3] has been deactivated or
charging process has been interrupted.
In operating mode:
Switch off (see section
).
Wait until SYS‑PST 1500 Li HP has
cooled down.
If LEDs continue to flash yellow, switch
off again (see section
) and leave to cool
down further.