Turbo II M
19
GB
3
Technical data
* The values mentioned are emissions values and
do not necessarily correspond to the standard of
work. In fact, there is a correlation between the
emissions and exposure values, but these cannot
be used reliably to determine whether further pre-
cautionary measures are unnecessary. Factors
which influence the actual level of exposure of the
workers include features of the workspace, other
sources of noise, etc., for example the number of
machines and other neighbouring work. The per-
missible exposure level may vary from country to
country. Using this information the user of the ma-
chine can make a better assessment of the dangers
and risks.
4
Intended use
The exhaust turbine
Turbo II M - 8 WP R1/ - 14 WP R1
– corresponds to dust class ’M’ according to IEC/
EN 60335-2-69 App. AA and is suitable for ex-
tracting hazardous dust with occupational expo-
sure limit values ≥ 0.1 mg/m³ as well as wood and
paint dust,
– designed exclusively for industrial use.
– Extracting dust with a Kst value > 200 (bar*m)/s
and/or an ignition energy < 10 mJ is not permit-
ted. Please observe local regulations.
– not suitable for extracting liquids.
Turbo II M - 8 WP R1/ - 14 WP R1 ATEX
– corresponds to dust class ’M’ according to IEC/
EN 60335-2-69 App. AA and is suitable for ex-
tracting hazardous dust with occupational expo-
sure limit values ≥ 0.1 mg/m³ as well as wood and
paint dust,
– is suitable for absorbing and extracting dry, com-
bustible and conductive dust at machines and de-
vices in Zone 22,
– designed exclusively for industrial use,
– suitable up to a total dust load of 160 g/min (8WP)
and 280 g/min (14WP).
– not suitable for extracting liquids.
Exhaust turbine
Turbo II M- 8 WP R1 Turbo II M- 14 WP R1
Power supply (input)
400 V 3~
400 V 3~
Mains frequency
50/60 Hz
50/60 Hz
Power consumption
7.5 kW
11 kW
Fuse
16 A
32 A
Compressed air supply
6 - 10 bar, not oiled
6 - 10 bar, not oiled
Max. volume flow (air)
850 m
3
/h
1230 m
3
/h
Nominal volume flow (admission rate 20 m/s)
565 m
3
/h
565 m
3
/h
Max. vacuum in normal operation
-180 hPa
- 180 hPa
Max. vacuum in the event of a fault (e.g. power failure)
-400 hPa
- 400 hPa
Sound pressure level as per EN 60704-1 and uncertainty
K (at 40 Hz) *
65 dB(A)
4 dB
66 dB(A)
4 dB
Filter surface area
4.8 m
2
7.2 m
2
Dimensions (LxWxH)
1045 x 805 x 1740 mm
1045 x 805 x 1740mm
Container capacity
50 l
50 l
Weight
306 kg
316 kg
Dust extraction, diameter of connection pipes
100 mm
100 mm
Protection category
IP 5x / IP 64 (ATEX)
IP 5x / IP 64 (ATEX)
Permissible ambient temperature in operation
0 - 45 °C
0 - 45 °C
Relative humidity
Max. 90%
Max. 90%
Residual dust content in circulating air
< 0.1 %
< 0.1 %
ATEX identification
CE 0637
II 3D Ex tc IIIC T135 °C Dc
0 °C ≤ Ta ≤ 45 °C X
EC-type examination certificate number
IBExU14ATEXB007 X
Summary of Contents for 10014766
Page 2: ...0 I 1 2 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 2 1 2 4 2 3 2 2...
Page 3: ...3 1 3 2 3 3 3 1 2 TURBO II 8WP 14WP R1 TURBO II 8WP 14WP R1 ATEX ENS TURBO II 499 904...
Page 5: ...5 1 5 2 5...
Page 6: ...6 1 6 Typ G 5x20 T2A Typ G 5x20 T1A 7 7A 7B...
Page 102: ...102 Turbo II M RUS 10 1 80 C 135 C M Festool 6 30 60 100 6 1...
Page 109: ...Turbo II M 109 RUS 10 1 3 3 2 3 1 3 3 8 5 W9 10 2 4 4 3 4 1 4 2 4 6 4 5 4 7 4 4 4 8 ATEX 4 5...