10
Technical data
Size
5
7
8
Stroke/cushioning distance s
[mm]
7.5
9.5
13.5
Male thread
M8x1
M10x1
M12x1
Mode of operation
Single-acting, pushing
Cushioning
Self-adjusting
Mounting position
Any
Max. mass
1)
[kg]
2
5
10
Max. energy absorption per stroke
at +20 °C
1)
[J]
1
2
3
Max. energy absorption per hour
at +20 °C
1)
[kJ]
10
15
21
Impact velocity
[m/s]
0.1 … 2
0.1 … 3
Min. insertion force F
2
[N]
5
18
80
Max. stop force at end position
[N]
200
300
500
Min. reset force F
1
[N]
1.5
2
3.5
Reset time at 20 °C
[s]
£
0.2
Reset time at 0 °C
[s]
£
1
Ambient temperature
[°C]
0 … +60
1) At higher temperatures in the range of 80 °C: the max. mass and the max. energy absorption are
reduced approximately 50%.
Tab. 9: Technical data