background image

Product

Thread size

Tightening torque [Nm]

VYKB-F10

M2

0.16 … 0.2

VYKB-F12

M3

0.27 … 0.33

7.2

Mounting of medium connection

Mount the fittings on the sub-base. Observe the following tightening torque:

Thread size

Tightening torque [Nm]

M6, 1/4-28 UNF

1.5 … 1.8

8

Installation

8.1

Fluid installation

1

2

3

4

Fig. 2: Fluid connections

1 Channel (1) "NC"
2 Channel (2) "COM"
3 Only 3/2-way valve: channel (3)

"NO"

4 Seal

8.2

Electrical installation

WARNING

Risk of Injury due to Electric Shock.
• For the electric power supply, use only PELV circuits that ensure a reliable

electric disconnection from the mains network.

• Observe IEC 60204-1/EN 60204-1.
• The unit must be powered by a power source that fulfils the requirements of an

energy-limited circuit in accordance with IEC 61010-1/EN 61010-1.

Note polarity (red cable = +).

Observe maximum cable length of 10 m.

Insert the plug.

9

Commissioning

Requirements

The product is fully mounted and connected.

Commissioning the product
1. Switch on the media supply.
2. Switch on the power supply.
3. Check the product for leakage.

10

Maintenance

Inspect the product regularly from the outside for leakage and function.

Clean the outside of the product as required with a soft dry cloth.

11

Disassembly

1. Switch off the power supply.
2. Depressurise the valve and medium line and allow them to cool.
3. Drain the medium line and valve completely. Collect the discharged media in a

suitable container.

4. Disassemble the valve. Do not pull on the cable. Unlock the locking lug when

removing the plug.

12

Technical data

VYKB

-F10

-F12

Technical data, general
Design

Rocker valve with diaphragm seal

Installation location

use only indoors

Mounting position

any

Degree of protection

IP40

Flow direction

non-reversible

Information on materials

Contains paint-wetting impairment substances

1)

Min. grid dimension with
block mounting

[mm]

11

13

Load

Vibration

severity level 2 in accordance with IEC 60068

Shock

severity level 2 in accordance with IEC 60068

Temperature range

Medium

[°C]

0 … 50

Environment

[°C]

0 … 50

VYKB

-F10

-F12

Storage

[°C]

−20 … +70

Port

fluidic

Flange with additional sub-base VABS; 1/4-28 UNF; M6

Electrical

Connecting cable NEBVHPG2-PN0.3NLE2

Technical data, fluidic
Medium

liquid media

gaseous media

Max. contamination level of
the medium

[µm]

5

Materials in contact with the
medium

PEEK, EPDM, FFKM, FKM

PEEK, EPDM

Pressure of medium

[MPa]

−0.075 … +0.1

−0.075 … +0.3

Flow rate Kv

[m³/h]

0.034

0.0558

Internal volume

[µl]

35

60

Technical data, electrical
Nominal operating voltage

VYKB-...-5

[V DC]

12 +10 %, −5 %

VYKB-...-1

[V DC]

24 ±10 %

Max. switching frequency

[Hz]

2

Duty cycle

[%]

100

Overvoltage category

II

Contamination level

2

2

Max. power consumption

Inrush current

VYKB-...-5

[W]

3.7

5.2

VYKB-...-1

[W]

3.7

4.5

Holding current

[W]

1

1

Inrush current

VYKB-...-5

[mA]

308

433

VYKB-...-1

[mA]

154

188

Holding current

VYKB-...-5

[mA]

83

84

VYKB-...-1

[mA]

42

42

1) PWIS = paint-wetting impairment substances

Tab. 3: Technical data

Type of severity level (SL)

Vibration load
Frequency range [Hz]

Acceleration [m/s

2

]

Deflection [mm]

SL1

SL2

SL1

SG2

SL1

SL2

 8

 8

±

3.5

±

3.5

 27

 27

10

10

27 

 58

27 

 60

±

0.15

±

0.35

58 

 160

60 

 160

20

50

160 

 200

160 

 200

10

10

Shock load
Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

SL1

SL2

SL1

SL2

SL1

SL2

±

150

±

300

11

11

5

5

Continuous shock load
Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

±

150

6

1000

Tab. 4: Type of severity level (SL)

Reviews: