Festo — VTOP — 2021-07
Technical data
27
13.3
Volume booster VOGM-FD100 -... 33...- M-F90
VOGM-FD100 -...
-M33E-M-F90
-T33H-M-F90
Design
Sub base valve
Function
Boosting the compressed air flow rate specified by the positioner
Method of operation
Single-acting
Double-acting
Ambient temperature
[°C]
–40 … +80
Transport and storage
temperature
[°C]
–40 … +80
Operating medium
Compressed air to ISO 8573-1:2010 [7:7:–]
Inert gas
Information on operating
medium
Lubricated operation not possible
Medium temperature
[°C]
–40 … +80
Operating pressure
[MPa]
0.14 … 0.8
[bar]
1.4 … 8
[psi]
20.3 … 116
Standard nominal flow
rate
[l/min] 1240
CE marking
See declaration of conformity
Product weight
[g]
1560
Tab. 11: Technical data – Volume booster VOGM-FD100 -... 33...- M-F90
Ratio of compressed air flow to flow control valve setting