5

Mounting

1. Place the VPPE-... as close to the consumer as possible. This improves control

precision and reduces response times.

2. Push two screws (M4) into the holes for lateral mounting 

è

 Fig.2, 

1

 or the

holes for front mounting 

è

 Fig.2, 

aB

, max. tightening torque: 2 Nm.

3. Mount the VPPE-... in the intended position.

NOTICE!

When installing the VPPE-…-E1T on the mounting rail IPM-PN-08-40x80-AL,
note that the compressed air supply corresponds to the total air consump-
tion. For more information see the assembly instructions for the VAME-PS-
MK.

6

Installation

6.1

Pneumatic installation

1. Remove the covers from the supply ports.
2. Attach the tubing to the following ports (

è

 Fig.2):

Input supply port (1), position 

2

Output supply port (2), position 

aJ

3. Mount a silencer at the exhaust supply port (3) (position 

aA

) or extract the

exhaust air using ducts.

Operating medium

NOTICE!

Too much residual oil content in the compressed air will reduce the service life of
the valve.

When using organic oils (oils that are based on synthetic esters or native
esters, e.g. rapeseed oil methyl ester), the maximum residual oil content of
0.1 mg/m³ must not be exceeded (

è

 Compressed air to ISO 8573-1:2010

[–:–:2]).

The position of the pneumatic ports depends on the variant ordered.

6.2

Electrical installation

WARNING!

Risk of injury due to electric shock.

For the electrical power supply, use only PELV circuits in accordance with IEC
60204-1/EN 60204-1 (Protective Extra-Low Voltage, PELV).

Observe the general requirements of IEC 60204-1/EN60204-1 for PELV cir-
cuits.

Only use voltage sources that ensure a reliable electric separation from the
mains network in accordance with IEC 60204-1/EN 60204-1.

Use the following connection accessories (

è

 3 Further information): 

plug socket with cable or

plug socket cable, pre-assembled.

This ensures that the specified degree of protection IP 65 and EMC is achieved.

NOTICE!

To guarantee EMC safety, the device must be earthed as follows:

Use the earth terminal (

è

 Fig.2

è

 Fig.3).

Use the following earthing accessories (included in the scope of delivery):

Self-tapping screw

Flat plug

Contact washer.

Wire the VPPE-... in accordance with the plug pattern. Preferably use Festo
cables.

Pin

Colour 

1)

Allocation

1

brown

+24 V DC

2

white

Analogue input - setpoint value/-w

3

blue

GND

4

black

Analogue input - setpoint value/+w
(0 … 10 V or 4 … 20 mA)

5

grey

Switching output (24 V) or
Analogue output (0 … 10 V or 4 … 20 mA)
Actual value/X

OUT

1) Colour is only valid for Festo accessory cables

Tab. 3 Pin allocation M12x1 plug, 5-pin

7

Commissioning

NOTICE!

The VPPE-... interprets setpoint signals less than 0.1 V as 0 V and setpoint sig-
nals less than 4.16 mA as 4 mA. In this case, the output pressure is set to 0
MPa by activation of the exhaust valve. As a result, a defined valve condition
is assured at w = 0.

Safety position: if the voltage variant setpoint value cable breaks, the output
pressure is set to 0 MPa. If the current variant cable breaks or if the supply
voltage fails, the output pressure is maintained uncontrolled. Leakage results
in a change of pressure over the long term.

1. Connect the VPPE-... with a setpoint value signal. The VPPE has a so-called

“differential input”. The setpoint signal is applied to the contact pin 2 and pin
4, where the lower potential must be connected to the contact pin 2 and the
higher potential to the contact pin 4.
Contact pin 2 (– setpoint value) can be connected to contact pin 3 (GND).

2. Energise the VPPE-... with direct current (supply voltage U

V

 = 24 V DC ± 10%).

3. Pressurise the VPPE-... to at least 0.1 MPa higher input pressure (p1) than the

maximum desired output pressure. This sets proportional output pressure
(p2).

The following output pressure range is then allocated to the setpoint value signal
range 0 … 10 V or 4 … 20 mA:

Output pressure range of the variant

Setpoint value
signal range

0.2 MPa

0.6 MPa

1 MPa

0 … 10 V or
4 … 20 mA

0.002 … 0.2 MPa

0.006 … 0.6 MPa

0.01 … 1 MPa

Tab. 4 Setpoint value signal range and associated output pressure range

7.1

Recommended parameter sets

The valves in all pressure variants are set at the factory to Preset 2.

Preset

Preset recommendation

1

2

3

Consumer volume

<

 0.5 l

~

 0.5 l

>

 0.5 l

Tab. 5 Recommended parameter sets

7.2

VPPE display and meaning

In the delivery status the display corresponds to the factory setting

è

 10.1 Reset to factory settings.

Display

Meaning

Description

[An]

Analogue

Output: analogue

[bAr]

bar

Pressure unit

[Eco]

ECO mode

Display shutdown (adjustable)

[Frc]

Force

Manual setpoint specification

[HY]

Hysteresis

Spread, switch difference

[in]

Setpoint value

When the 

v

 button is pressed (1 sec.), [in]

appears. The setpoint value is displayed when
the button is released.

[Loc]

Lock

Input locked with PIN code

[n.Hi]

Switch normally closed

N/C contact (normally closed)

[n.Lo]

Switch normally open

N/O contact (normally open)

[OFS]

Offset

Zero point increase
(Outlet pressure without setpoint value)

[out]

Actual value

When the 

v

 button is pressed (1 sec.), [out]

appears. The actual value is displayed when the
button is released.

[PA]

Kilo

pascal

Pressure unit (in 

k

Pa!)

[Pin]

Pin code

Enter value for locking
(1 … 999)

[Pr1]

Preset 1

(

è

 7.1 Recommended parameter sets

[Pr2]

Preset 2

(

è

 7.1 Recommended parameter sets

[Pr3]

Preset 3

(

è

 7.1 Recommended parameter sets

[PSi]

psi

Pressure unit

[rES]

Reset
(factory setting)

Switch on device while pressing 

V

 + 

v

 + Edit

buttons. Observe note in section

è

 10.1 Reset to factory settings.

[rnG]

Range

Pressure range adjustment

[Snr]

Display serial number

Switch on device while pressing 

v

 + Edit but-

tons: 6-digit serial number is displayed, first
[xxx.] then [xxx] alternating approx. every 2 sec.

[SOF]

Display software version

Switch on device while pressing 

V

 + Edit keys:

software version appears

[SP]

Switching point

è

 6.2 Electrical installation

[SP.H]

Switching Point high

Upper switching point

è

 6.2 Electrical installation

[SP.L]

Switching Point low

Lower switching point

è

 6.2 Electrical installation

[SP.O.]

Set Point ok

Setpoint value reached

è

 6.2 Electrical installation

[unL]

Unlock

Lock removed

Threshold value comparator

è

 6.2 Electrical installation

Window comparator

è

 6.2 Electrical installation

[._..]

ECO mode activated

A line moves through the display [._..] after x
seconds (adjustable)

Tab. 6 Indication on display

Summary of Contents for VPPE-3-1-1/8 E1 Series

Page 1: ...t in accordance to IEC EN UL CSA 61010 1 or on a Limited Power Source LPS in accordance to IEC EN UL CSA 60950 1 or IEC EN UL CSA 62368 1 or a Class 2 circuit in accordance to NEC or CEC Electrical data and ambient conditions Supply voltage 24 V DC Max power 4 2 W Rated pressure up to 1 1 MPa Max installation height 2000 m Tab 2 3 Further information Accessories è www festo com catalogue Spare par...

Page 2: ...s maintained uncontrolled Leakage results in a change of pressure over the long term 1 Connect the VPPE with a setpoint value signal The VPPE has a so called differential input The setpoint signal is applied to the contact pin 2 and pin 4 where the lower potential must be connected to the contact pin 2 and the higher potential to the contact pin 4 Contact pin 2 setpoint value can be connected to c...

Page 3: ...on option v V 1 x xx v 1 sec in V 1 sec out 2 Pr Pr Pr1 Pr2 Pr3 3 bAr bAr bAr PA PSI 4 OFS 5 rnG 6 Frc 0 00 10 0 V voltage variant 4 00 20 0 mA current variant 7 An An SP O SP SP L HY HY SP H n Lo n Hi n Lo n Hi n Lo n Hi HY n Lo n Hi n Lo n Hi n Lo n Hi 8 Eco OFF OFF 1 999 sec 9 Pin OFF OFF 1 999 back to no 1 Tab 8 7 5 Preparation 8 Operation NOTICE When switching off the VPPE make sure that the ...

Page 4: ...e of protection IP 65 in combination with connector socket according to accessories Permissible temperature range Environment C 0 60 Storage C 10 60 Medium C 10 50 Electrical connection Pin contact M12x1 5 pin Permitted supply voltage 24 V DC 10 Setpoint variable input resistance 0 10 V 4 20 mA 10 kΩ voltage 250 Ω current Load actual value output min 2 kΩ voltage max 500 Ω current Residual ripple ...

Reviews: