VOFA−...
Festo VOFA−... 1004NH English
58
Vertical stacking variant
The vertical stacking variant is supplied together with the VTSA−... pre−assembled
from the factory. No further assembly steps are required prior to installation.
Information on the H−rail or wall mounting of the valve terminal can be found in the
description
Pneumatic VTSA−...
"
, type P.BE−VTSA−44−...
Pneumatic
Note
·
Before mounting, remove particles in the supply lines through appropriate
measures. In this way, you protect the control block from premature failure
and higher wear.
·
Also observe the specifications on compressed air quality in the technical
data.
Decentralised individual connection variants
·
Connect with tubing the ports for operating pressure (1), exhaust air (3)/(5)
and working pressure (2)/(4) using fittings with connecting thread 1/4
"
.
Accessories for the tubing connection of the ports can be found in our catalogue
è
www.festo.com/catalogue in the internet.
Electrical
Caution
Danger of electric shock at contacts of the solenoid coils
·
Create the electrical connection only in a voltage−free status and only by
qualified personnel.
·
Use only plugs according to DIN EN 175301−803, type C.
Protection against electric shock (protection against direct and indirect contact) is
guaranteed in accordance with IEC/DIN EN 60204−1 by using PE
L
V circuits
(electrical equipment of machines, general requirements).
Summary of Contents for VOFA-B26-T52-M Series
Page 26: ...VOFA Festo VOFA 1004NH Deutsch 26 Bild 11 Funktionstest Schritte 1 bis 4...
Page 27: ...VOFA Festo VOFA 1004NH Deutsch 27 Bild 12 Funktionstest Schritte 5 bis 7...
Page 64: ...VOFA Festo VOFA 1004NH English 64 Fig 11 Function test steps 1 to 4...
Page 65: ...VOFA Festo VOFA 1004NH English 65 Fig 12 Function test steps 5 to 7...