Assembly instructions (Original: de)
8059653
1606
†‡
Manifold rail
VABM-L1-...HWS1/2-...-GR
Festo AG & Co. KG
Postfach
73726 Esslingen
Germany
+49 711 347-0
www.festo.com
1.
Parts list
2220
4d_1
1
Manifold
rail
(1x)
VABM-L1-...HWS1/2-...-GR
2
Blanking
plug
B-1/8
3
Plug
assembly
Not included in delivery:
(1x)
(1x)
22204d_8
22204d_7
4
Supply
plate
VABF-L1-...-P3A4-...-T1
5
Blanking plate VABB-L1-...-T
6
Solenoid valve VUVG-...
7
Fixed restrictor VFFG-T-F...
8
Check valve VABF-L1-...H-H2
9
QS fitting (
table)
aJ
Electrical
interface
VAEM-L1-S-...
aA
Blanking plug B-M7
2.
Safety instructions and notes on mounting
Switch off compressed air before mounting work.
Do not interchange outputs 2 and 4 of the components during the mount-
ing procedure.
VABM-L1- 10HWS
14HWS
(C)
ß
Z1
0.3 Nm + 50 %
ß
Z1
0.55 Nm ± 50 %
(D)
ß
T10
0.7 Nm ± 20 %
ß
T10
0.7 Nm ± 20 %
2
ß
5
1.5 Nm – 20 %
ß
5
1.5 Nm – 20 %
7
ß
2
2.0 Nm ± 15 %
ß
2.5
2.0 Nm ± 15 %
8 ß
2
1.2 Nm ± 15 %
ß
2.5
2.0 Nm ± 15 %
9
M5 M7 G1/8
G1/4
G3/8
[Nm]
1.5 – 30 %
1.5 – 20 %
5.0 – 20 %
8.5 ± 15 %
8.5 ± 15 %
Form pressure zones with the VABD-…-B separator.
(
assembly instructions for separator: VABD-...-B).
To feed additional operating pressure into the pressure zones or increase the
exhaust performance:
Mount supply plate
4
on manifold rail
1
.
In case of unused valve positions:
Mount blanking plates
5
.
3.
Mounting of blanking plug
2
/plug assembly
3
22
20
4d
_5
With external pilot air:
Push plug assembly
3
into
port 14 (A).
With internal pilot air:
Screw blanking plug
2
into
the port 14 (A).
Screw both blanking
plugs
aA
into the
ports 14 (B).
Info
For dismantling plug assembly
3
use the M4 thread (X).
4.
Assembly of supply plate
4
/blanking plate
5
/solenoid valve
6
22
20
4d
_3
Place the compo-
nents
4
/
5
/
6
on the mani-
fold rail
1
.
Tighten screws (C). Use a
Phillips head screwdriver Z1.
If applicable, place addition-
al components
4
/
5
/
6
as
desired.
5.
Assembly of fixed restrictor
7
/check valve
8
/QS fitting
9
222
04d
_4
Screw the QS fittings
9
into
channels 1, 3 and 5, as well
as the ports 14 and 84.
Screw QS fittings
9
into the
respective outputs 2 and 4.
Screw the fixed restrictors
7
/check valves
8
into the channels 3 and 5 of
manifold
1
thereby forming a thread until they sit flush. If you screw it in
again, use the threads already present.
6.
Mounting of electrical interface
aJ
Note
If the plug is bent during mounting, the function of the electrical interface
aJ
can no longer be guaranteed.
Mount and plug the electrical interface
aA
parallel to the terminal strip.
22
20
4d
_2
Place the electrical inter-
face
aJ
on the manifold
rail
1
.
Tighten the screws (D)
1)
.
Use a T10 TORX screwdriver.
7.
Mounting to the control cabinet
22204
d_9
Use control cabinet cut-out
contour
www.festo.com/sp
Place the manifold rail
1
on
the control cabinet cut-out.
Tighten M5 screws.
8.
Earthing
Note
Incorrect or missing earthing can cause malfunctions due to electromagnetic
interference.
Connect the earth terminal (E) to the earth potential. Shim the earthing
screw, e.g. with a toothed disc (F). The toothed disc (F) penetrates the
anodised coating of the manifold rail
1
.
Conductive connection established.
1
1)
The variants VAEM-L1-S-M3-26/-50 have only 2 mounting screws (D) each.
1
1
aJ
E
3
2
A
4
/
5
/
6
1
C
9
1
aA
B
aA
D
F
M5 x 10 mm
1
2
3
9
7
/
8
X
4
5
6
9
aJ aA
7 8
1