7.3
Restoring factory settings
•
To restore the factory settings, press the "Preset" button in the FMT.
The vacuum generator is delivered with 4 default parameter sets. These parameter sets are divided
according to the product version:
–
Vacuum type: high vacuum [-VH] or high suction volume flow [-VL].
–
With or without air saving function (LS)
Parameter set
0
[-VH] with LS
1)
1
[-VL] with LS
1)
2
[-VH] without
LS
2)
3
[-VL] without
LS
2)
Switching point A1
75 kPa
40 kPa
70 kPa
40 kPa
Switching point A2
97 kPa
67 kPa
0 kPa
0 kPa
Hysteresis A
25 kPa
25 kPa
25 kPa
10 kPa
Air-saving function
Active
Active
Inactive
Inactive
Switching point B1
55 kPa
20 kPa
50 kPa
20 kPa
Switching point B2
71 kPa
41 kPa
71 kPa
41 kPa
Hysteresis B
20 kPa
10 kPa
20 kPa
10 kPa
Process quality monitoring
50 %
50 %
50 %
50 %
threshold evacuation time
0
0
0
0
threshold air supply time
0
0
0
0
1) channel A + B: window comparator
2) channel A: threshold value comparator; channel B: window comparator
Tab. 14 Default parameter sets
8
Parameter description
8.1
Module parameters
Parameter
Factory setting
Description
Short circuit monitoring
Inactive
Short-circuit monitoring deactivated
Open load monitoring
Active
Open load monitoring activated
Process diagnosis
Inactive
Process diagnosis deactivated
Tab. 15 Diagnostic parameters
Parameter
Factory setting
Description
Ejector pulse locked
Inactive
Interlock ejector pulse deactivated
Operating mode
Data record mode
Selection of mode of operation
Tab. 16 Function parameters
Parameter description
25
Festo — VABF-S4-...-CB-VH/VL-... — 2019-05