Commissioning instructions
Setting the PROFIBUS address
You can set the PROFIBUS address (DP slave address) of the
SPC200 with the software package WinPISA or with the opera-
ting panel. Modification by a DP master is not possible.
Number of configurable inputs and outputs
The SPC200 communicates with the PROFIBUS master via an
I/O field (internal inputs/outputs). The permitted number of con-
figurable inputs and outputs depends on the operating mode of
the SPC200. This is summarized in the following table.
Operating
mode of the
SPC200
Max. address
range *)
Function of the inputs/outputs
Start/Stop
I10.0 - I13.15
I10.0 - I10.15
for control signals and
freely prog. inputs
I11.0 - I13.15
for freely programmable
inputs
(optional)
Q10.0 - Q13.15
Q10.0...Q10.15
for control signals and
freely prog. outputs
Q11.0 - Q13.15
for freely programmable
outputs
(optional)
Record
selection
I10.0 - I11.15
I10.0 - I10.15
for control signals
I11.0 - I11.15
for record number
Q10.0 - Q10.15
Q10.0 - Q10.15
for control signals
*) Address specification as seeen by the SPC200