Festo SOPA Operating Instructions Manual Download Page 4

5.2.3

Wall mounting

1

2

2

Fig.10

1

Adapter plate for wall mounting

2

Adapter plate

1. Mount the adapter plates on the wall.

Hole patterns and dimensions 

è

 12.3 Hole patterns.

2. Attach the sensor to the adapter plates and press until the fastening slide

locks.

5.3

Using sensor module without control module

The supply pressure can be fed from the left and the right-hand side.

1

1

Fig. 11: Attach the sensor modules

1

Connection for supply pressure

1. Mount the fitting on the supply pressure port.

Thread M7, thread length: max. 5.5 mm

2. Seal the exposed port with a blanking plug.

A/F: 3 mm

5.4

Accessories

Identifier

Type

Connecting cable

Straight socket

NEBU-M12G5-K-...

Angled socket

NEBU-M12W5-K-...

Differential pressure regulator

LRLL-1/8-QS-6

Adapter plate for wall mounting

1)

SXE3-...-W...

Blanking plug

B-M7

Push-in fitting

QSM-M7-6-I

1) Included in the scope of delivery for SOPA-...-W-...

Tab. 8: SOPA accessories

6

Installation

6.1

Pneumatic Installation

1

2

2

Fig. 12: Pneumatic Installation

1 Control module

2 Sensor module

1. Insert tubing into push-in fitting.

Outside diameter: 6 mm

2. Connect the supply port for the measuring nozzle to the corresponding meas-

uring nozzle 

è

 Fig. 3.

3. For operation with a control module: connect supply port for operating

medium to the compressed air source.
For operation without a control module: connect the supply port for the
supply pressure to the precision pressure regulator.

4. Ensure adequate exhaust at the vent screw connection (via vent screw or

differential pressure regulator (LRLL-1/8-QS-6) 

è

 Fig. 1.

Tubing at Standstill

To avoid contamination of the measuring nozzles, remove the vent screw and
use this connection to supply purge air.

6.2

Electrical installation

WARNING

Risk of injury due to electric shock.
• For the electrical power supply, use only PELV circuits in accordance with IEC

60204-1/EN 60204-1 (Protective Extra-Low Voltage, PELV).

• Observe the general requirements of IEC 60204-1/EN 60204-1 for PELV circuits.
• Only use voltage sources that ensure a reliable electric separation from the

mains network in accordance with IEC 60204-1/EN 60204-1.

1. Use signal lines that are shorter than 30 m.
2. Configure binary outputs according to the wiring (only with PNLK sensor

modules).

Tightening torque for the union nut at the plug connector: 0.3 Nm

6.2.1

PIN allocation and control module circuit diagrams

Pin

Wire colour

1)

Allocation

Plug

1

Brown (BN)

Operating v24 V DC

M12, 5-pin

2

White (WH)

Switch on signal input exhaust air (Clean)

3

Blue (BU)

Operating voltage 0 V

4

Black (BK)

Switch on measuring air signal input
(Sense)

5

Grey (GY)

n.c = free (not connected)

1) When using the connecting cable from the accessories.

Tab. 9: Pin allocation for control module

SOPA-C..-H-...-2P-...

1)

SOPA-C..-H-...-2N-...

BN

BK

BU

+24 V

0 V

WH

PNP

1

4

3

2

5

Sense

Clean

BN

BK

BU

+24 V

0 V

WH

NPN

1

4

3

2

5

Sense

Clean

1) in combination with PNLK sensor modules

Tab. 10: Circuit diagrams for control module with manual override

SOPA-C-...-2P-...

1)

SOPA-C-...-2N-...

BK

BU

+24 V

0 V

WH

PNP

1

4

3

2

5

Sense

Clean

BN

BK

+24 V

0 V

WH

NPN

1

4

3

2

5

Sense

Clean

1) in combination with PNLK sensor modules

Tab. 11: Circuit diagrams for control module without manual override

6.2.2

PIN allocation and sensor module circuit diagrams

SOPA-...-2P/-2N

Pin

Wire colour

1)

Allocation

Plug

1

Brown (BN)

Operating v24 V DC

M12, 5-pin

2

White (WH)

Switching output for OutB or OutC (factory
setting)

3

Blue (BU)

Operating voltage 0 V

4

Black (BK)

Switching output for OutA

5

Grey (GY)

n.c = free (not connected)

1) When using the connecting cable from the accessories.

Tab. 12: Pin allocation for sensor module

SOPA-...-2P-M12-...

SOPA-...-2N-M12-...

BN

BK

BU

R

L

+24 V

0 V

WH

P

R

L

PNP

1

4

3

2

5

BN

BK

BU

+24 V

0 V

WH

P

NPN

1

4

3

2

5

R

L

R

L

Tab. 13: Circuit diagrams for sensor module

SOPA-...-PNLK

Pin

Wire colour

1)

Allocation

Plug

1

Brown (BN)

Operating v24 V DC

M12, 5-pin

2

White (WH)

Analogue output

3

Blue (BU)

Operating voltage 0 V

4

Black (BK)

Switching output for OutA or OutC (C/Q
line with IO-Link)

5

Grey (GY)

n.c = free (not connected)

1) When using the connecting cable from the accessories.

Tab. 14: Pin allocation for sensor module

Summary of Contents for SOPA

Page 1: ...tegory code NRNT2 NRNT8 File number E253738 Considered standards UL 508 CSA22 2 No 14 UL mark Tab 2 UL CSA certification information This device is intended to be used with a Class 2 power source or C...

Page 2: ...max flash SHOW mode active 7 segment display shows the minimum or maximum value InC Marked segments light and Option flashes EDIT mode active Special menu opens 7 segment display shows the set option...

Page 3: ...Pmax IO Link SP1 SPmin SP2 SPmax no TEACH mode Tab 7 Window comparator with switching point SP and hysteresis HY Hysteresis Hysteresis serves to suppress switching signals in the event of fluctuations...

Page 4: ...204 1 for PELV circuits Only use voltage sources that ensure a reliable electric separation from the mains network in accordance with IEC 60204 1 EN 60204 1 1 Use signal lines that are shorter than 30...

Page 5: ...onds RUN mode is active Option 2 teaching in the switching point for OutA 1 Establish the desired switching distance between the object and the meas uring nozzle 2 Press and hold the A pushbutton 3 Al...

Page 6: ...nger displayed 4 If the delay SUP P in the display is too great reduce the time by turning the control valve towards HIGH 9 Maintenance and Care 1 Switch off the energy sources operating voltage compr...

Page 7: ...resent Electronic Rated operating voltage V DC 24 Operating voltage V DC 15 0 30 0 20 0 30 0 22 8 26 4 No load supply current mA 50 10 Reverse polarity protection for all electrical connections Electr...

Page 8: ...1 193 IODD IO Link device description www festo com sp Tab 21 IO Link 12 2 Diagrams Response times for different tube lengths Fig 17 Typical response time t as a function of distance x after switching...