SFAW
24
Festo – SFAW – 1602a English
Parameter
1)
Adjustable values
Factory setting
[SP] with flow
measurement
5…100 % full scale
2)
60 % full scale
2)
[SP.Lo] with flow
measurement
5…99 % full scale
2)
60 % full scale
2)
[SP.Hi] with flow
measurement
5.5…100 % full scale
2)
70 % full scale
2)
[HY] with flow
measurement
0…90 % full scale
2)
0.5 % full scale
2)
[SP] with temperature
measurement
1…90 % full scale
40 % full scale
[SP.Lo] with temperature
measurement
1…89.5 % full scale
40 % full scale
[SP.Hi] with temperature
measurement
1.5…90 % full scale
60 % full scale
[HY] with temperature
measurement
0…80 % full scale
0.5 % full scale
[logic]
NO, NC
NO
[COLR]
bLUE, R.ON, R.OFF
bLUE
[SP] with volume measu
rement
è
11 Technical data
SFAW-32-…: 32,0 l
SFAW-100-…: 100,0 l
[PULS]
10…1000 MSEC
100 MSEC
[FLOW] [Unit]
l/Min, l/h, CFM, GPM
l/Min
[Out]
0…10 V, 1…5 V, 4…20 MA
0…10 V
[In.Hi]
10…100 % Full Scale
100 % Full Scale
[In.Lo]
0…90 % Full Scale
0 % Full Scale
[VOL] [Unit]
Ltr, M^3 (m
3
), CFt, GAL
Ltr
[tEMP] [Unit]
°C, °F
°C
[Filt]
100, 150, 300, 650, 1200, 2500, 5000,
10000 MSEC
150 MSEC
[Eco]
di.ON, 5, 10, 20, 40, 80, 160, 320, 640 s
di.ON
[bin] [Out]
PNP, NPN
PNP
[bin] [Pin4]
FLOW, VOL
FLOW
[bin] or [ANLG] [Pin2]
FLOW, tEMP
FLOW
[ANLG] [Pin5]
FLOW, tEMP
FLOW
[Lock] [Code]
OFF, 1…9999
OFF
[MASt]
OFF, ON
OFF
1)
All parameters of the complete menu structure are listed. Some menu options or setting values are not applicable, depending on
the product variant and the selected switching function.
2)
The values refer to the respective measuring range.
Tab. 12
Adjustable values and factory setting