7

Malfunctions

7.1

Diagnostics via LEDs

Display

Meaning

Measure

Status indication:

Piston outside the sensing range

Piston not at switching point

Normal operating case

Both LEDs
off

Error:

Power supply fault

Connecting cable or sensor defective

Check power supply

Check connecting cable

Replace device

Green LED
flashes at
6 Hz

Hardware error

Disconnect and connect proximity
sensor

Replace device

Tab. 5 

7.2

General malfunctions

Error description

Possible cause

Measures/remedy

Proximity sensor defective

Replace proximity sensor

Operating voltage not connected
or outside the operating voltage
range

Comply with operating
voltage range

Short circuit or overload at the
output

Rectify short circuit/over­
load

Magnetic or ferromagnetic objects
close to the proximity sensor

Keep magnetic or ferromag­
netic objects clear of the
proximity sensor

Conditions during teach­in of
the switching point must cor­
respond to operating condi­
tions (e.g. no screwdriver in
the locking screw)

Incorrect or unexpected
signals at the output

Orientation of the proximity
sensor rotated 180° in the slot
after adjustment of the switching
point

Reset switching point (with
auto teach­in or operating
key)

Proximity sensor defective

Replace proximity sensor

Switching output does not
react in accordance with
the settings

Short circuit or overload at the
output

Rectify short circuit/over­
load

Capacitive operating key
does not react to input

Dirt or moisture on the proximity
sensor

Wipe proximity sensor with a
dry cloth

Tab. 6 

8

Technical data

SDBT-MSX

Operating voltage range

[V DC]

10  … 30

Max. output current

[mA]

100

Operating temperature range

[°C]

–40 … +85 (UL: +80)

Ambient temperature with
flexible cable installation

[°C]

–20 … +85 (UL: +80)

Degree of protection
(EN 60529)

IP 65 / IP 68

Tab. 7 