Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 53
Vision Sensor Manual
If you know the IP-address of a sensor, please enter it into the field IP-address and click button "Add".
Now the sensor appears in the list and can be accessed for e.g. Config or View.
If the function "Config" is not accessible (button not active / greyed out) a Login with password input is
necessary. If you do not know the password please contact your site systems administrator.
4.5.4 Configuring a connected sensor
Mark a sensor (simulation) in the list and click on the "Config" button.
The configuration program Vision Sensor Configuration Studio is called up and the jobs currently stored
on the sensor are shown in the selection list.
When Vision Sensor Configuration Studio is called up, you may be required to enter a password. See
User administration / Passwords (Page 54)
for defining passwords.
s. chap Vision Sensor Configuration Studio
SBS – Operating- and configuration software – Vision Sensor
Configuration Studio, all functions
4.5.5 Display images and result data
Mark a sensor in the list and click on the "View" button.
The Vision Sensor Visualisation Studio program is opened up and images and measurement results from
the active jobs are displayed on screen.
Information:
Calling up Vision Sensor Visualisation Studio does not affect operation of the selected sensor.
s. chap. Vision Sensor Visualisation Studio
SBS – Operating- and configuration software – Vision Sensor
Visualisation Studio, all functions
4.5.6 Sensor's network settings
You can change the network settings of the selected sensor with the Set button.
The IP address, subnet mask, standard gateway, DHCP and sensor name can be set here.
The PC's IP address and subnet mask are displayed below in the Vision Sensor Device Manager status bar.
The address structure must be correct in order to be able to connect the sensor to the PC. The sensor's
IP address etc. can therefore be modified accordingly here if necessary.
Please contact your site administrator for the definition of network parameters. Further information on
this subject can be found in the printed manual.
If "DHCP = active" is selected, a unique name must be given for the sensor as the IP address is newly
assigned each time the sensor starts up and can thus change.
You require administrator authorisation for these functions (see user administration).