3.
D
i
agn
o
s
i
s
C
P
V
−D
I02 (
P
R
OF
I
BUS−DP
)
3
−
13
Fes
to
P
.
B
E
−
C
P
V
−D
I02
−
E N
en
070
4
N
H
3.2.
4
De
t
a
il
s
for
s
t
anda
r
d
d
i
agn
o
s
ti
c
i
n
for
ma
tio
n
Th
e
followi
ng
d
i
agn
o
s
ti
c
i
n
for
ma
tio
n
can
be
r
eq
u
s
t
ed
b
y th
e
DP
mas
t
e
r fro
m
th
e
C
P
I
s
y
s
t
em
vi
a
th
e
fu
nc
tio
n
Sl
a
v
e
_D
i
a
g
.
Th
e
C
P
I
s
y
s
t
em
r
e
pli
es
with
an
o
c
t
e
t
s
tri
ng
of l
eng
th 10. Th
e
pro
ced
ur
e
for r
ead
i
ng
out thi
s
d
i
agn
o
s
ti
c
i
n
for
ma
tio
n
with
a
S
IMATIC
S
5
/S
7
s
y
s
t
em
i
s
desc
ri
bed
i
n
sec
tio
O
c
tet
1: S
t
a
ti
o
n
s
t
a
tu
s
_1
B
it
M
e
a
nin
g
E
xpl
a
n
a
ti
o
n
0
D
i
a
g.S
t
a
ti
o
n
_No
n
_
E
x
i
s
tent
C
P
I
s
y
s
t
em
n
o lo
nge
r
/n
ot y
e
t
add
r
essab
l
e
.
P
o
ss
i
b
l
e
ca
u
ses:
O
p
e
r
a
ti
ng
volt
age
n
ot
a
ppli
ed
Da
t
a
cab
l
e
i
n
t
e
rrupt
ed
Fa
ult i
n
da
t
a
cab
l
e
1
D
i
a
g.S
t
a
ti
o
n
_No
t
_R
e
a
dy
C
P
I
s
y
s
t
em
n
ot y
e
t r
ead
y for
da
t
a
e
x
c
h
ange
2
D
i
a
g.
C
fg_F
a
u
l
t
Th
e
c
o
n
fi
g
ur
a
tio
n
da
t
a
r
ece
iv
ed
fro
m
th
e
mas
t
e
r
d
o
n
ot
ag
r
ee
with tho
se
asce
rt
a
i
ned
b
y th
e
C
P
I
s
y
s
t
em
.
3
D
i
a
g.
E
x
t
_D
i
a
g
Th
e
r
e
i
s
a
de
vi
ce−
r
e
l
a
t
ed
d
i
agn
o
s
i
s
.
P
o
ss
i
b
l
e
ca
u
ses:
C
ab
l
e
fr
ac
tur
e
o
n
i
n
put
/
output
m
o
d
ul
e
S
hort
c
ir
c
uit
/
ov
e
rlo
ad
a
t
e
l
ec
tri
c
output
s
or
sens
or
s
upply for i
n
put
s
V
v
a
lv
es
.
20.
4
V
V
output
s
.
10 V
V
sens
or
.
10 V
4
D
i
ag
.Not_
S
upport
ed
1
=
C
P
I
s
y
s
t
em
d
o
es
n
ot
s
upport th
e
fu
nc
tio
n
r
eq
u
es
t
ed
5
D
i
ag
.I
n
v
a
li
d
_
S
l
a
v
e
_R
es
po
nse
a
lw
a
y
s
0 (
se
t
b
y C
P
I
s
y
s
t
em
)
6
D
i
ag
.
P
r
m
_
Fa
ult
L
as
t p
a
r
ame
tri
z
i
ng
t
e
l
eg
r
am
f
a
ulty
7
D
i
ag
.M
as
t
e
r_Lo
ck
a
lw
a
y
s
0 (
se
t
b
y C
P
I
s
y
s
t
em
)
bold
=
v
a
lv
e
t
e
r
m
i
na
l r
e
l
a
t
ed
b
it
s
T
ab
.3
/
8
:
D
i
agn
o
s
ti
c
b
it
s
s
t
a
tio
n
s
t
a
tu
s
1
Summary of Contents for PROFIBUD-DP
Page 2: ......
Page 15: ...Installation CPV DI02 and CPV CS02 1 1 Festo P BE CPV DI02 EN en 0704NH Chapter 1...
Page 58: ...1 Installation CPV DI02 and CPV CS02 1 44 Festo P BE CPV DI02 EN en 0704NH...
Page 59: ...Commissioning CPV DI02 PROFIBUS DP 2 1 Festo P BE CPV DI02 EN en 0704NH Chapter 2...
Page 79: ...Diagnosis CPV DI02 PROFIBUS DP 3 1 Festo P BE CPV DI02 EN en 0704NH Chapter 3...
Page 107: ...Commissioning CPV CS02 ABB CS31 4 1 Festo P BE CPV DI02 EN en 0704NH Chapter 4...
Page 116: ...4 Commissioning CPV CS02 ABB CS31 4 10 Festo P BE CPV DI02 EN en 0704NH...
Page 117: ...Diagnosis CPV CS02 ABB CS31 5 1 Festo P BE CPV DI02 EN en 0704NH Chapter 5...
Page 131: ...Technical appendix A 1 Festo P BE CPV DI02 EN en 0704NH Appendix A...
Page 146: ...A Technical appendix A 16 Festo P BE CPV DI02 EN en 0704NH...
Page 147: ...Index B 1 Festo P BE CPV DI02 EN en 0704NH Appendix B...
Page 148: ...B Index B 2 Festo P BE CPV DI02 EN en 0704NH Contents B Index B 1...
Page 154: ...B Index C 8 Festo P BE CPV DI02 EN en 0704NH...